Troubleshooting issues with BMC Helix CMDB
Here are some common problems that can arise in implementations:
- Import and reconciliation take significant time
Make sure that only business-critical information is stored in the . Use federation for access to real-time or secondary information. Make sure that the database server is connected to through a 100MB or 1GB network link. If you add custom workflow to forms, test it with high data-load scenarios and confirm that you do not see time-outs. - Reconciliation Engine cannot identify instances
Make sure that proper discovery options are used so identification attributes have non-null unique values. - Configuration items have multiple instances (duplicates)
Make sure that import datasets have accurate data and that identification rules are working correctly for each dataset. - Class Manager changes are left pending
Only change the class model if absolutely required. Restrict access in the Class Manager to a single user. Make attribute changes one at a time and wait for changes to complete before proceeding. Changes to BMC_BaseElement can take two hours or longer. Class model is out-of-sync with underlying
forms
Except for the look and feel, do not use BMC Remedy Administrator to edit -related forms in . Always use the user interface instead.- Adapter.OpenConnection completed with errors issued StartDataHandlers: Vendor Data Handler failed to start
Verify that you specified the correct user name and password. Also test the external data store connection by using the Test Connection button on the Connection Settings tab before you trigger the data exchange. - Filter/escalation 'set fields' process timed out before completion. Set fields active link running a process failed
From the AR System Administration Console, click System > General > Server Information > Timeouts. Also increase the Process Timeout setting for . The default value for the Timeout setting is 5 seconds. - Cannot run the requested process. Set fields active link running a process failed
Verify whether the installer copied the aiexfer utility in the installation Directory. If not, verify whether BMC Atrium Integration Engine was successfully installed. - Required field cannot be reset to a NULL value PCT:Product Catalog
Product Categorization Tier 1" - Ensure that following fields Category, Type, Item and Manufacturer Name are mapped. Dataset which you are using for Data transfer should be selected as Trusted in Dataset form.
For more information, see the Troubleshooting section of the BMC Atrium Core documentation.
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*