Issues tables


Review the following tables for issues that were corrected in BMC Helix Telco Extensions 25.1.00 and for known issues that remain open.

Corrected issues

View the issues in the following tables by the default sort order, Corrected in, which shows the corrected issues first. 

The version number represents the update (Year.Month.Release) or release number (MajorRelease.MinorRelease.ServicePack.Patch) in which the issue is fixed.

Known (open) issues

To view only the open issues, click the Corrected in filter, and select empty. An issue without a value for Corrected in remains open.

You can also filter and sort issues according to affected version (versions in which the issue exists), component, or defect ID. 

Known and corrected issues

ComponentDescriptionStatusFound inDefect ID
Incident requestsWhen a parent ticket has two child tickets and the service desk agent resolves one child ticket and removes the second child ticket from the parent-child relationship, the parent ticket is automatically incorrectly resolved.Open23.3.04DR7O8-1505
Alarm management

For an incident with alarms, when you click on view details, select the secondary alarm with invalid CIs, and click Make primary, the following error messages are displayed:

Error (245002) Could not properly update the Incident, so the transaction has been rolled back.

Error (45670) Please select a CI from the menu provided or search for a CI by pressing the CI search button.
Open23.3.01DR7O8-834
Alarm management

When you enable the primary alarm, the Refresh button and the Alarm Filter option is not displayed.

Workaround: Delete some alarms for the options to be displayed.

Open23.3.01DR708-572
Incident requests

When you add a user with Incident Viewer permissions as a Related party to an existing incident ticket and the user opens that incident ticket through the Ticket Console, the following error message is displayed:

You are not authorized to access this page.

Workaround: Give the user the following additional permissions:
Incident User, Service Request User, and Work Order User.

Open

23.3.01

DR708-489

Incident requests

While viewing the alarm details, when you click on the Filter option and scroll down the page to click Apply, the filter grid is not displayed.

Workaround: Reduce the screen resolution.

Open

23.3.02

DR7O8-1023

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

BMC Helix Telco Extensions 25.1