Deploying and Configuring IBM SVC-Storwize ETL 10.7.01 for TrueSight Capacity Optimization
This topic contains the following sections:
Compatibility details
BMC TrueSight Capacity Optimization
BMC TrueSight Capacity Optimization v10.7.00 and later
IBM SVC-Storwize systems
IBM Hardware | Supported versions of the embedded CIM Agent |
|---|---|
IBM SVC | 7.2.0.14 |
IBM Storwize V7000 | 7.4.0.22 |
For more recent versions, please contact our support team.
Prerequisites
IBM SVC-Storwize ETL for TrueSight Capacity Optimization leverages the embedded SMI-S provider to collect capacity information about IBM SVC and Storwize storage systems.
The embedded SMI-S provider is automatically activated and the ETL accesses it via port 5989 (default). A user with security/Admin or administrator role is required.
Deploying the ETL module
Complete the following steps to deploy the ETL Module:
- Navigate to Administration > SYSTEM > Maintenance.
- Verify the installation status of the already uploaded packages. If their status is "READY" or "RUNNING", wait for the installation to complete before proceeding.
- At the bottom of the Maintenance page, locate the Upload patch or additional package file section.
- Click Browse.
- Locate and select the ETL installation package.
- Click Upload.
- Read the Overview and click Next to continue.
- Read and accept the End User License Agreement.
- Select the server on which the operation must be executed; that is the server on which the package will be saved. Click Proceed to continue.
A successful installation will result in a green line in the Additional Packages table.
Configuring the ETL module
Complete the following steps to configure an ETL service and add it as an ETL task to extract capacity and performance metrics:
- Navigate to Administration > ETL & SYSTEM TASKS > ETL tasks.
- In the ETL tasks page, under the Last run tab, click Add > Add ETL. The Add ETL page is displayed.
- In the Run configuration tab, in the ETL module property, select Storage - IBM SVC-Storwize CIM Agent Extractor Service

Specify values for the common and advanced properties that are listed under the expandable tabs. To view or configure advanced properties, click Advanced.
For details about the common properties, see Common configuration properties. The following table lists the properties that are specific to the IBM SVC-Storwize ETL module:Property
Description
Connection settings
Hostname
Hostname or IP address of the server where the IBM SVC-Storwize CIM Agent is running.
Port
Port number used by the IBM SVC-Storwize CIM Agent (Default: 5989).
Connect As
Username to connect to the IBM SVC-Storwize CIM Agent (Default: admin).
Password
Password to connect to the IBM SVC-Storwize CIM Agent.
Transport Protocol
Transport protocol used by the IBM SVC-Storwize CIM Agent (for HTTP, the default port is 5988; for HTTPS, the default port is 5989).
ETL additional settings
Volumes
This property allows you to disable or enable volumes monitoring and fine-tune the creation of volume entities in the BMC TrueSight Capacity Optimization environment. For more information, refer to the section "Customizing Volumes Monitoring" below.
Property
Description
Collection level
Levels up to
By default, extended level metrics are not imported by the ETL. To import them, you will have to customize the collection level and set it to [4] Extended.
For more information about Aging Class Mapping, refer to the topic Adding and modifying metrics profile.
Post-configuration steps
- Testing the connection to the embedded SMI-S Provider
- Customizing volumes monitoring
- Running the Extractor Service task
- Setting the collect frequency
Testing the connection to the embedded SMI-S Provider
The ETL relies on the embedded SMI-S Provider to collect information about IBM SVC-Storwize storage systems. Because some connectivity issues may exist and cause the ETL to fail, it is highly recommended to test the connection to this specific component. The procedure is as follows:
- Download the troubleshooting tool from EPD.
- Run the command java –jar <Troubleshooting_Tool_Name.jar> to launch the tool.
- Enter the information required to connect to the system and click Test Connection.
- Wait for the test to complete.
- If a connectivity issue is detected, an error message will appear. In this case, the issue encountered does not concern the ETL. Check your configuration to diagnose the source of the issue.
- Click Save As to export the connection test results into a txt file.
Customizing volumes monitoring
Discovering volumes and collecting their performance metrics are resource-intensive actions that can create extra workload on the system. To reduce the system resource consumption, administrators can disable or enable the volumes monitoring at will and fine-tune the creation of volume entities into the BMC TrueSight Capacity Optimization environment.
The following metrics are no longer collected and displayed in the console when volumes monitoring is disabled:
Dataset | Metrics |
|---|---|
STOGLB |
|
STOHOST |
|
To customize volumes monitoring
- Edit the ETL Run Configuration.
- Expand the ETL additional settings menu.
From the Volumes pull-down lists, select one of the following options:
Option
Result
Disabled
- Volumes are not discovered.
- Volumes-related metrics are not loaded in the console.
Collected for metric computation (Default)
- All volumes are discovered and their metrics are collected and processed.
- Volumes-related metrics are not loaded in the console.
Collected and Imported
- All volumes are discovered and their metrics are collected and processed.
- Volumes-related metrics are saved in the database, processed and loaded in the console.
- Click Save.
Running the Extractor Service task
Setting the collect frequency
Lookup details
IBM SVC-Storwize ETL for TrueSight Capacity Optimization defines the following lookup fields:
Entity type | Lookup fields |
|---|---|
Storage System | DEFAULT |
Storage Pool | DEFAULT |
Storage Volume | DEFAULT |
icon to inspect the deployment log.
to execute the ETL task.