Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Datastream for z/OS 7.1.

SMF TSS80 fields


These fields are for CA Top Secret. 

TSS SMF 80 records are for legacy MVS events.

Name

(Filter)

Tag

CEF Name

Description

FLAACC


AccAllow


Allowed access, expressed in hex

FLAACCD

(Mapped Integer)

AccAllow


Allowed access, expressed in text

FLACID

(EGNX)

AcidNm


Acid name

FLAID


AcidID


Acid ID

FLATTR


Attr


User attributes

FLCATP


Options


If FLSVC=X'1A' this = CTGOPTNS

FLCLASS

(EGNX)

Class


Resource class

FLCLASS2


ResClass


Two-byte resource code

FLCLASSD

(Mapped Integer)

ClassD


Resource class, expressed in text

FLDATE


FLDATE


Date (packed YYDDDF)

FLDETLRC

(Integer)

Reas


Detail reason code, expressed as an integer

FLDETLRCD

(Mapped Integer)

Reas


Detail reason code, expressed in text

FLDID


DeptID


Dept ID

FLEVENT


FLEVENT


Security-event (SKEVENT)

FLFLAGS


LogReas


Logging indicators (SKLOGF)

FLFLAGS_Audit

(Boolean)

LogReas_Audit


Logging indicators (SKLOGF) — Audit

FLFLAGS_Forced

(Boolean)

LogReas_Forced


Logging indicators (SKLOGF) — Forced

FLFLAGS_ForceMsg

(Boolean)

LogReas_ForceMsg


Logging indicators (SKLOGF) — Force message to user

FLFLAGS_NoIO

(Boolean)

LogReas_NoIO


Logging indicators (SKLOGF) — Do not perform I/O

FLFLAGS_NoSMF

(Boolean)

LogReas_NoSMF


Logging indicators (SKLOGF) — Don’t write SMF record

FLFLAGS_SendMsg

(Boolean)

LogReas_SendMsg


Logging indicators (SKLOGF) — Send message by ID

FLFLAGS_TrueFail

(Boolean)

LogReas_TrueFail


Logging indicators (SKLOGF) — True failure

FLFLAGS_Violation

(Boolean)

LogReas_Violation


Logging indicators (SKLOGF) — Violation

FLGRPUID

(EGNX)

FLGRPUID


VM group userid

FLIND1

(Mapped Integer)

Indic1


Indicators

FLIND2


AuditReason


The audit reason expressed as text: Action, Resource, User, Facility, Volume, or DSN

FLINDEV

(EGNX)

Dev


Input device (terminal/reader)

FLJOB

(EGNX)

FLJOB


Job name

FLJOBID


JobID


Job ID (JES format)

FLJOBNUM

(Integer)



Job number (JES format)

FLJOBTYP

(Integer)

Type


Jobtype

FLLOCK


FLLOCK


Lockbyte X'FF' when in use

FLMODE

(EGNX)

Mode


User's mode

FLMODULE

(Mapped Integer)

ModNm


Security module (SKLOGM)

FLNVIOL


FLNVIOL


Violation count (for session)

FLOGOPTS


FLOGOPTS


Copy of user's logging options

FLPGM

(EGNX)

Prog

sourceServiceName

Program in control

FLRACC


AccReq


Requested access, expressed in hex

FLRACCD

(Mapped Integer)

AccReq


Requested access, expressed in text

FLRDTE


FLRDTE


Reader start date

FLREADY


FLREADY


X'FF' when buffer complete

FLRESL

(Integer)

FLRESL


Machine length of resource V5L0JL01

FLRETCOD

(Integer)

RC

act

Return code

FLRTME


FLRTME


Reader start time

FLSTCK

(Integer)

FLSTCK


CPU time entry given

FLSVC


SVC


Calling SVC, expressed in hex

FLSVCD

(Mapped Integer)

SVC


Calling SVC, expressed in text

FLTIME


FLTIME


Time of day (HHMMSSTH)

FLTYPNUM

(EGNX)



Type (S=STC,J=JOB,....)

FLVAR


Data


Variable data (if 1-byte resource class)

This field is formatted only if FLVAR is correctly formatted in the SMF record.

FLVAR_Inc

(EGNX)

Data


Variable data (if 1-byte resource class)

This field is formatted only if FLVAR is incorrectly formatted in the SMF record.

FLVAR_APF

(Boolean)

APF


APF authorization status of the resource dataset name

For more information, see SMF-record-enrichment

FLVAR2

(EGNX)

Data


Variable data (if 2-byte resource class)

FLVOLSER

(EGNX)

Vol


Volume serial

SMF80CAT

(EGNX)

Cat

cat

Constant TSS80

SMF80DESD


Desc


Descriptor flags

The SMF field names and descriptions are derived from CA Top Secret for z/OS documentation.

 