Information
Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Datastream for Db2 7.1.

SMF 110 statement


If properly configured, CICS writes performance records as SMF Type 110 records.

SMF-110.png

severity.png

For information about  filterSpecification , see FILTER-and-MATCH-parameters.

You might need to monitor CICS SMF records to maintain an audit trail of sensitive transactions. If you code an SMF 110 statement, all SMF Type 110 records with a subtype of 1 and a class of 3 are forwarded to your BMC Defender Server or syslog console with a facility of LOCAL0 (3) and a severity of informational. BMC AMI Datastream supports compressed CICS SMF records: the support is automatic; there is no specific option that must be enabled in BMC AMI Datastream.

If you code more than one SMF 110 statement, then a subsequent SMF 110 statement replaces any SMF 110 statement(s) that came before.

BMC AMI Datastream supports the following types of CICS SMF record fields:

Subtype

Class

Data record type

Field names

Common

SMFMNxxx

1 – Monitoring

3 – Performance

DFH xxxx_xxxxx (deprecated)
TMRxxxxx

5 – Resource

Common (ID)

MNR_ID_xxxxx

File

MNR_FILE_xxxxx

TS Queue

MNR_TSQ_xxxxx

DPL (distributed link)

MNR_DPL_xxxxx

Support for CICS TS Version 5.5 has been added to BMC AMI Datastream. CICS TS Version 5.5 is still in beta and certain fields might be changing. If you experience incorrectly formatted performance fields, contact BMC Support.

For performance reasons, BMC AMI Datastream caches any DFHMCT customization on a per-CICS-applid basis. If you re-customize and stop and start a CICS subsystem, see SET(CICS) under MODIFY-command.

If you are using CICS user performance class data fields (DFHMCT TYPE=EMP), contact BMC Support.

Unlike other SMF record types, one SMF Type 110 record might be (and usually is) formatted into more than one syslog message. An SMF Type 110 subtype 1 SMF record might (and usually does) contain more than one CICS data record; if so, each is formatted into a separate syslog message.

Parameter

Description

SMF 110

Must be specified as shown.

FACILITY(facilityName)

Specifies the RFC 3164 facility that is to be indicated as the origin of the syslog records corresponding to SMF 110 records

If you omit this parameter, it defaults to LOCAL0. If you would like a different facility indicated, code one of the RFC 3164 facility names as listed in Syslog-facilities-and-severities.

FIELDs(fieldName…)

Specifies the names of the CICS SMF record fields that are to be transmitted to the BMC Defender Server or other syslog console, and the order where they are to appear in the message

Specify one or more of the fields as described in Supported-SMF-field-names.

filterSpecification

For information about  filterSpecification , see FILTER-and-MATCH-parameters.

INHibit

Specifies that the writing of the SMF record type 110 to the SMF datasets, logstream, or both are to be inhibited by BMC AMI Datastream

SMF record type 110 is processed by BMC AMI Datastream, but then inhibited from further processing by SMF.

LOG | LOG(HEX)

Specifies that the selected SMF records are to be logged on CZAPRINT and optionally dumped in hexadecimal and character format

Compressed records are dumped both before and after decompression. This parameter is intended primarily for diagnostic purposes. Use care in specifying LOG(HEX) as it might have generated a large volume of print records, especially if BMC AMI Datastream is left running for several hours or more.

MONitor()

Specifies one or more CICS monitoring classes and the syslog severity to be assigned to them

Specify one or more of the following monitoring classes (refer to the table): PERFormance, RESource.

SEVerity(severity) specifies the syslog severity for the specified monitoring classes. See Syslog-facilities-and-severities. You might have also code DEFAULT or SUPPRESS. DEFAULT indicates that the severity is to default to the defined severity; SUPPRESS indicates that the specified event records are not to be forwarded to the syslog server at all.

PROCess(‘processTag’)

Specifies the tag that appears at the start of SMF 110 syslog messages, following the priority, timestamp and hostname, and preceding the formatted fields

Specify the exact process tag that you need to include in syslog messages including any spaces and punctuation. Process-tag might be any length from the null string (‘’) to 32 characters. If SMF 110 PROCess is omitted, it defaults to CICS followed by the leading delimiter from OPTIONS DELIM.

SEVerity(severity)

Specifies the default syslog severity

You might also code SUPPRESS. SUPPRESS indicates that the default is that records are not to be formatted and forwarded to the syslog server at all. If you omit SEVerity, it defaults to INFOrmational. For more information, see Syslog-facilities-and-severities.

 