SYSPLEXOFFSET
Syntax
SYSPLEXOFFSET value SID= list
Syntax explanations
Value has the following syntax
SDDDHHMM
S—+ or - sign ('+' sign can be omitted)
DDD—number of days
HH—number of hours
MM—number of minutes
- List is a list of system IDs for which the SYSPLEXOFFSET value applies. Each system ID that you specify in this list must be separated from the others by a comma. There can be no blank spaces in the list.
Rules
- All parameters are required.
- The SYSPLEX Timer Offset (Hypervisor Date/Time Offset) is reported by RMF in the type 70 record (field SMF70HOF). The SYSPLEXOFFSET command is required by UIE because it does not require sorting of the input records and allows for processing records in any order as they are read. However, the value specified in the SYSPLEXOFFSET command must match the value reported in the RMF type 70 record.
Examples
SYSPLEXOFFSET +0100000 SID=SYSA
In this example, the SYSPLEXOFFSET for system SYSA is 10 days ahead of the current date and time.