Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Monitor for z/OS 6.3.

Installing distributed alarm definitions (optional)


MainView for z/OS ships distributed alarm definitions in BBACTDEF member BBDTDA.

The ALRMDIST view, as shown in the following figure, lists the distributed alarm definitions, which can be installed by either typing ADD on the COMMAND line or using an ADD line command.

Note

ALRMDIST writes the alarm definition directly to the MainView for UNIX System Services file system. Your PAS must have an OMVS segment and must be authorized to write to the directory specified for alarm definitions in the CAS.

DDMMMYYYY  HH:MM:SS -------- MainView WINDOW INTERFACE (Vv.r.mm) ----------------
COMMAND  ===>                                                    SCROLL ===> CSR
CURR WIN ===> 1        ALT WIN ===>                                                                                                
>W1 =ALRMDIST==========SJSCDAVM=*=========DDMMMYYYY==HH:MM:SS====MVMVS====D==13
- Distributed Alarms                                 - Hide Fixed Section      
                       Replace NO                                              
CMD Alarm            Library          Group            Description             
--- Name--------     ------------     ------------     ------------            
    BBDCF000         BMC              MVMVS            CF CPU utilization excep
    BBDCF001         BMC              MVMVS            CF storage utilization e
    BBDCF002         BMC              MVMVS            CF structure storage exc
    BBDCPU00         BMC              MVMVS            High CPU utilization    
    BBDCSA00         BMC              MVMVS            CSA Max threshold except
    BBDCSA01         BMC              MVMVS            CSA allocated by termina
    BBDDEV00         BMC              MVMVS            DASD slow down          
    BBDDEV01         BMC              MVMVS            Device response time exc
    BBDJES00         BMC              MVMVS            Required jobs not runnin
    BBDJOB00         BMC              MVMVS            Delayed due to resource
    BBDJOB01         BMC              MVMVS            Job CPU exceptions      
    BBDRSV00         BMC              MVMVS            DASD RESERVE exceptions
    BBDWLM00         BMC              MVMVS            Jobs are not meeting PI

For additional information regarding alarms for MainView for z/OS, see MainView-Alarm-Management.

 