Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Monitor for IP 3.9.

Saving Packet Trace data upon recycle of MainView for IP PAS


Use the following procedure to save Packet Trace data to a data set upon recycle of the MainView for IP PAS.

Before you begin

You must allocate a data set before you can save Packet Trace upon recycle of the MainView for IP PAS. This process is not performed within the program. Allocate the data set with the following attributes:

  • Organization: PS
  • Record format: VB
  • Record Length: 27998
  • Block Size: 32760

To save Packet Trace data upon recycle of the MainView for IP PAS

  1. From the EZIP menu, select Product Administration (EZADMIN) in the Utilities section, and press Enter.
  2. From the EZADMIN menu, select MVIP Configuration Settings (MVIPCNFD), and press Enter.
  3. In the Save Pkt at Shutdown field, type YES or NO to enable or disable saving of Packet Trace data.
  4. In the Packet Trace File field, type the name of the data set where MainView for IP should write the Trace data when the PAS is shut down.



 