Saving Packet Trace data upon recycle of MainView for IP PAS
Use the following procedure to save Packet Trace data to a data set upon recycle of the MainView for IP PAS.
Before you begin
You must allocate a data set before you can save Packet Trace upon recycle of the MainView for IP PAS. This process is not performed within the program. Allocate the data set with the following attributes:
- Organization: PS
- Record format: VB
- Record Length: 27998
- Block Size: 32760
To save Packet Trace data upon recycle of the MainView for IP PAS
- From the EZIP menu, select Product Administration (EZADMIN) in the Utilities section, and press Enter.
- From the EZADMIN menu, select MVIP Configuration Settings (MVIPCNFD), and press Enter.
- In the Save Pkt at Shutdown field, type YES or NO to enable or disable saving of Packet Trace data.
- In the Packet Trace File field, type the name of the data set where MainView for IP should write the Trace data when the PAS is shut down.