Enabling TN3270 response time data collection


Use the following procedure to enable TN3270 response time data collection.

Warning

Note

For more information, see the IBM z/OS Communications Server: IP Configuration Reference.

To enable TN3270 response time data collection

  1. In the BEGINVTAM section of the Telnet Server Profile data sets, add MONITORGROUP statements to define the data collection options.Options for the MONITORGROUP statement include the inclusion and exclusion of averages, counts by time bucket, and whether the IP network should be included in measurements.
  2. In the same section, add MONITORMAP statements, to map the connection identifiers to the data collection options that the MONITORGROUP statements defined.When a MONITORGROUP is mapped to Client Identifiers with the MONITORMAP statement, the requested data is collected for those connections.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*