Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, seeBMC AMI Ops Monitor for IMS Online 5.5.

Collecting extended data


You can use the DCIOAL, EMIOAL, FFIOAL, and FPIOAL parameters in BBPARM member IMFBEX00 to control the maximum length of the I/O area copied into the detail trace for specific call types.

The default for each parameter is 64 bytes of data, and the maximum length you can specify is 65536. If you specify 0 for a parameter, no I/O area data is captured for that data type.

For information about the BBPARM IMFBEX00 member, seeCustomizing MainView for IMS and MainView for DBCTL. To determine the current settings in IMFBEX00, use the IBEXSUMR view.

Note

Your changes affect all detail traces, not just the new trace.

To change the I/O area parameters

  1. Make the parameter changes in BBPARM member IMFBEX00.
  2. Issue the reset command .E PARM IMFBEX00.
  3. Start a new detail trace.


 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*