Diagnostic codes for PRSPLT00
The following messages and codes might be issued during PRSPLT00 verification of control statements and execution:
Code | Explanation |
---|---|
0 | All the control statements specified are shown Code 0 represents normal processing. |
1 | Unrecognized keyword |
2 | Unable to locate requested module |
3 | Summarization period larger than plot interval specification (specify DATE as the first parameter) |
4 | Bad XAXIS specification |
5 | Program interruption |
6 | No plot, array empty, or selection criteria not applicable This return code is issued when no data could be collected to plot. The corresponding plot is not produced. This message may occur as a result of the MainView for IMS product data collection options. |
7 | Numeric string not null or terminated with a delimiter |
8 | Last select statement missing |
A | *Data overflow - decrease plot period - retry* |
The following figure provides an example of a Graphical Analysis Facility Diagnostics report:
GRAPHICAL ANALYSIS FACILITY DIAGNOSTICS
CODE MESSAGE
0 ->REPORT=(TC,PS,EP,BP,OP,MP,DP,ET)
0 -> YAXIS=SCALE=MAX
0 -> SELECT=ALL
0 ->REPORT=(NX)
0 -> XAXIS=(DATE=07001/07365,TIME=07.00/19.00,INTERVAL=96)
0 -> YAXIS=SCALE=100
0 -> SELECT=ALL
0 ->REPORT=(AQ,EC,ER,PD)
0 -> YAXIS=SCALE=MAX
0 -> SELECT=ALL
0 -> LET
EOFSYSN1 0 ->****COMMAND PROCESSING FUNCTIONS COMPLETED.