Modifying request options and attributes


Use the M (Modify) line command to change the options and attributes for the selected monitor service request. The following Modify Resource Monitor Request dialog is displayed:

                         Modify Resource Monitor Request                         
  COMMAND ===>                                              SCROLL ===> CSR   
                                                                            
                       MXTC  - CICS MAXIMUM TASK PCT                           
  Monitor Attributes:                                                          
  PARM     CREGION      (Identifier)       START 19:00:00 (hh:mm:ss)           
  INTERVAL 00:00:10     (hh:mm:ss)         STOP  ________ (hh:mm:ss/mins)      
  WVAL     100_____     (Warning value)    WIF   1__      (Intvls to 1st msg)  
  WMSG     ________     (Log warnings to)  WIN   1 _      (Message Intervals)  
  WLIM     10           (Warnings limit)   RST   HOT      (HOT,PUR,QIS)        
                                           QIS   YES      (YES/NO)             
  TITLE   CICS MAXIMUM TASK PCT                                                
  PLOTMAX ___________                  (Maximum PLOT X-Axis value)             
  RANGES                               (1-4 Range Distr. Upper Limits)         
  LOG     NO                           (NO,ATSTOP,ATPD,ATINTVL,ATWARN)         
                                                                             
                                                                              
  END to quit the dialog                                                       
  HELP to view related help





 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

MainView for CICS 7.1