Starting a monitor
Use the following procedure to start a monitor.
To start a monitor
Type SM or MONSERV on the COMMAND line of any view and press Enter.The Start Monitors (SM or MONSERV) view is displayed and it lists all available monitors.
Start Monitors (SM or MONSERV) view
ddmmmyyyy hh:mm:ss ------ MAINVIEW WINDOW INTERFACE (Vv.r.mm) ----------------
COMMAND ===> SCROLL ===> PAGE
CURR WIN ===> 1 ALT WIN ===>
W1 =SM===============(BCVDVPC==*=======)ddmmmyyyy==hh:mm:ss====MVCICS===D====1
- Monitor Services
Commands: BLK (Requests) JOURNAL (Log Display)
Line CMDs: S (Select), L (Lock), U (unlock), H(Help)
CMD Service Num Title Parm Type Area
--- ------- Actv -------------------------- -------------- -----
#DSAV DSA PAGES AVAILABLE STOR
#DSIZ TOTAL DSA SIZE STOR
#DSTO DSA AVAILABLE STORAGE STOR
#ESAV EDSA PAGES AVAILABLE STOR
#ESIZ TOTAL EDSA SIZE STOR
#ESTO EDSA AVAILABLE STORAGE STOR
#PROC TRANS PROCESSED (IDENTIFIER) WKLD
@ACBN VTAM ACB Closed GENL
@CMXT CLASS MAX TASK % TASK
@DB2N DB2 Not Attached GENL
@ELAP AVG ELAPSED TIME (IDENTIFIER) WKLD
@GLBD CICS TD DFHINTRA USED % GENL
@GLBE CICS EXT-PRIVATE USED % GENL
@GLBM CICS TS MAIN IN USE GENL
@GLBP CICS PRIVATE STG USED % GENL
@GLBT CICS TOTAL CPU % GENL
@GLBU CICS USER CPU % GENLIn the CMD field next to the service that you want to start, type S and press Enter.Depending on the type of monitor that you select, a monitor-specific dialog is displayed. The following figure shows an example of a workload dialog display.
Start Workload Monitor dialog
Start Workload Monitor
COMMAND ===> SCROLL ===> CSR
MORE: +
#PROC - TRANS PROCESSED
Monitor Attributes:
PARM (Identifier) START (hh:mm:ss)
INTERVAL 00:01:00 (hh:mm:ss) STOP (hh:mm:ss/mins)
WVAL (Warning value) WIF 1 (Intvls to 1st msg)
WMSG (Log warnings to) WIN 1 (Message Intervals)
WLIM 10 (Warnings limit) RST HOT (HOT,PUR,QIS)
QIS YES (YES/NO)
TITLE TRANS PROCESSED
PLOTMAX (Maximum PLOT X-Axis value)
RANGES (1-4 Range Distr. Upper Limits)
LOG (NO,ATSTOP,ATPD,ATINTVL,ATWARN)
Specify Workload Selections:
TRAN
PROG
TERM
USERID
CLASS
PGMTYPE (NOATI, NOPRT or Program Type)
Specify Workload Exclusions (Exclude even if match above selections)
TRAN
PROG
TERM
USERID
MORE N (Y/N,*-processed)Specify the monitor service criteria:
Field
Description
Default
PARM
unique name for the request or a parameter for the monitor
For more information about the monitor that you want to start, see Monitor-reference
blanks
START
when to start the monitor service
next full minute
INTERVAL
time interval between successive service invocations
not applicable
STOP
when to stop the monitor service
24 hours
WVAL
warning threshold for the monitor request
0, no warnings
WIF
number of intervals before the first warning message
1
WMSG
where the warning messages are to be sent
LOG
WIN
number of intervals between warning messages
1
WLIM
maximum number of warning messages
10
RST
restart option to be used when a service is quiesced because of an inactive target region
HOT
QIS
action to be taken when a target is not active
YES
TITLE
display title for the monitor service (see Monitor-request-title)
name of the service
PLOTMAX
maximum value to be shown on the X-axis boundary for a PLOT of this monitor request
not applicable
RANGES
from one to four upper-range limit values for the PLOT range distribution
no range
LOG
logging option specification for the monitor service
no logging
Specify Workload Selections
criteria used to limit or filter monitor data collection to a specific part of the workload
not applicable
For additional information about a field, press F1 for online Help.