Replicating a monitor service request


Use the following procedure to replicate a monitor service request.

  1. Type AT or MONACTV on the COMMAND line of any view and press Enter.The following Active Monitors (AT or MONACTV) view is displayed.

    Success

    Tip

    To learn about a monitor service, type H in the CMD field next to the service and press Enter. A description of the service, its parameters, and the syntax of its warning message are displayed.

    To learn about a field on the Active Monitors view, position the cursor on the field and press F1 for online Help.

     

    Active Monitors (AT or MONACTV) view
    ddmmmyyyy  hh:mm:ss ------ MAINVIEW WINDOW INTERFACE (Vv.r.mm) ----------------
    COMMAND  ===>                                                 SCROLL ===> PAGE
    CURR WIN ===> 1        ALT WIN ===>                                            
     W1 =AT===============(BCVDVPC==*=======)ddmmmyyyy==hh:mm:ss====MVCICS===D====1
    -                         Monitors Active                                      
      Commands:  SM (Start Monitors)           MONSUMM     MONWARN     JOURNAL     
      Line CMDs: S (Select),  W (Show),       M (Modify)                           
                 P (Purge),   R (Replicate),  Z (Stop),  H (Help)                  
                                                                                  
    CM Serv  Parm     Title                   Monitor Warning                      
    -- ----- -------- ----------------------- Value   Value     -8-6-4-2-0+2+4+6+8+
       #DSTO          DSA AVAILABLE STORAGE    675.8K  1.0000 |          W         
       #ESTO          EDSA AVAILABLE STORAGE     4.9M  100.0  | >>>>>>>>>W>>>>>>>>>
       @TSKA          TASK STORAGE USAGE ABOV    4.9K  1.0000 | >>>>>>>>>W>>>>>>>>>
       @TSKS          TASK STORAGE USAGE         4.9K  1.0000 |          W         
       #ESAV          EDSA PAGES AVAILABLE       1.2K 10.0000 | >>>>>>>>>W>>>>>>>>>
       DSUT           CICS DSA UTILIZATION    78.0000  1.0000 |          W         
       CSUT           CSA % UTILIZATION       60.0000  1.0000 | <<<<<<<<<w<<<<<<<<<
       ECSUT          ECSA % UTILIZATION      56.0000  1.0000 | <<<<<<<<<w<<<<<<<<<
       #DSAV          DSA PAGES AVAILABLE       165.0 10.0000            W      
  2. In the CM field of the request whose values you want to copy, type R and press Enter.

    An example of a Replicate Resource Monitor dialog is displayed (see the following figure), with the values from the copied request duplicated in the dialog.

    Replicate Resource Monitor
                          Replicate Resource Monitor        
    COMMAND ===>                                              SCROLL ===> CSR   
                                                                                
                          #DSTO - DSA AVAILABLE STORAGE                          
    Monitor Attributes:                                                         
    PARM     ________ (Identifier)          START ________ (hh:mm:ss)           
    INTERVAL ________ (hh:mm:ss)            STOP  ________ (hh:mm:ss/mins)      
    WVAL     ________ (Warning value)       WIF   ________ (Intvls to 1st msg)  
    WMSG     ________ (Log warnings to)     WIN   ________ (Message Intervals)  
    WLIM     ________ (Warnings limit)      RST   ________ (HOT,PUR,QIS)        
                                            QIS   ________ (YES/NO)             
    TITLE    DSA AVAILABLE STORAGE                                              
    PLOTMAX ___________________________  (Maximum PLOT X-Axis value)            
    RANGES  ___________________________  (1-4 Range Distr. Upper Limits)        
    LOG     ___________________________  (NO,ATSTOP,ATPD,ATINTVL,ATWARN)        
                                                                                
                                                                                
    ENTER to process the request                                                
    END to cancel the request                                                   
    HELP to display related help
  3. (optional) Adjust the values as needed.To change a value, type over it.

    For additional information about a field, press F1 for online Help.

  4. Press Enter.The monitor service request is started and the Active Monitors (AT or MONACTV) view is displayed with the new request listed.

 