Set the CTG monitoring parameters in member CMRBEXnn
Update your CMRBEXnn member with the global monitoring parameter CTGMON and target monitoring parameter CTGNAME.
The CTGMON parameter controls whether CTG monitoring is on or off.
CTGMON=NO | YES
Specifies whether CTG monitoring should be active. Default is NO.
The CTGMON parameter options are described below.
MAXGATE=nnn
Indicates the maximum number of gateways the PAS will manage. The value must be in range of 1-100. Default is 20.
DSPLIM=nnnn
Indicates the size in megabytes of the home data space used by the PAS to manage communication with the gateway. The value must be in range of 100-2048. Default is 2048.
There can only be one CTGMON parameter in CMRBEXnn (any additional CTGMON parameters are ignored).
See Starting-and-resetting-CTG-monitoring for information about resetting parameters.
Define the CTGs to be monitored with CTGNAME parameter and its options.