Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops SYSPROG Services 6.3.

WARNING


The WARNING (WAR) service (alias AEW) provides the ability to start and stop the Exception Monitor and display and alter the parameters for active samplers.

For an explanation of the various samplers and their parameters, see Exception-Monitor-samplers.

Note

The WARNING (AEW) service is not supported when MainView SYSPROG Services is executed as a TSO command.

Syntax

image2017-5-26 13:26:11.png
The parameters are defined as follows:

 

Parameter

Description

LIST

lists the Exception Monitor samplers currently active (default)

START

starts the Exception Monitor system

If xx is not specified, BBPARM member PWSCPM00 is used.

xx

is the suffix used to form the name of the BBPARM member (PWSCPM xx) that contains the sampler control statements to be used to start the Exception Monitor

The default member name is PWSCPM00.

STOP

stops the Exception Monitor

STATS

displays a status report detailing the CPU time used by the Exception Monitor

This report is also displayed when the Exception Manager is stopped.

samp(n)

WARNING samp causes all parameters and their associated values for sampler samp to be displayed

(n) is optional and refers to the nth sampler with the name samp. The default value is 1. See examples 6 and 7.

parm

WARNING samp, parm causes the value associated with parameter parm for sampler samp to be displayed

PARM=value

WARNING samp, parm= value causes parameter parm for sampler samp to be set to value value

You can specify multiple parameters and values for the sampler on a single WARN command. You can also use scaled numeric values. See example 7.

Example 1

To display the active Exception Monitor samplers, type

WARN

WARN                                         
AMTTH2I The following AEW Samplers are active:       
AMTTH3I INT     DEV     DNR     MTP

Example 2

To start the Exception Monitor, type

WARN,START,01

WARN,START,01                                              
PWSSDV02 AEW Initializing                                          
PWSINI00 AEW parameters obtained from member PWSCPM01              
PWSSDV65 AEW Monitor Active,  5:00:24 PM, SJSD, Release: 3.6.00    
PWSSDV09 AEW Initialization Complete                               
AMTAW1I AEW initialization completed

Example 3

To display the status report, type

WARN,STATS

AMTV31I                       TCB Time  Rate                
AMTV32I  Sampler      Calls   Microsec  Microsec   Percent  
AMTV33I  ---------  --------  --------  --------  --------  
AMTV34I  GBLS           184     5,231        28       0.24  
AMTV34I  JSU            184     2,039K   11,083      95.06  
AMTV34I  Admin         -N/A-      101K      273       4.68  
AMTV33I  ---------  --------  --------  --------  --------  
AMTV34I  Total/Avg      368     2,145K    5,829     100.00  
AMTV35I Average absorption rate 1.400 seconds per hour      


AMTV36I  AEW DIE Monitor Statistics                         
AMTV37I                     Total   Nano Secs               
AMTV38I  DIE    Samples   Mic Sec  Per sample               
AMTV39I  ----  --------  --------  ----------               
AMTV3AI  GBLS   44,650       142K      3,173                
AMTV3AI  JSU    44,650       399K      8,947

Example 4

To display all of the parameters and their associated values for the DNR sampler, type

WARN,DNR

WARN,DNR                  
AMTTL8I DNR parameter value(s):   
AMTW51I INT = 1                   
AMTW51I NOTREADY = 2

Example 5

To display the value associated with PENDING parameter for the MTP sampler, type

WARN,MTP,PENDING

WARN,MTP,PENDING  
AMTW51I PENDING = 3

Example 6

To change the value of the PENDING parameter for the MTP sampler to 5, type

WARN,MTP,PENDING=5

WARN,MTP,PENDING=5
AMTW51I PENDING = 5

Example 7

This example shows how to use the WARNING service to change the minimum service units rate threshold (minrate) for the third BSRV sampler to 10,000 service units per second.

Because there are multiple BSRV samplers and the parameters for the third BSRV sampler needs updating, you must add the suffix (3) to the sampler name (BSRV(3)). The rate is a numeric value and you can specify a scaled value. In this example, the scaled value 10K represents 10,000 service units per second. This example also shows that the report interval value is 2 (INT=2).

You can specify both the rate and interval parameters at the same time; enter the following command to receive the following results.

WARN,BSRV(3),RATE=10K,INT=2

AMT000I WARN,BSRV(3),MINRATE=10K,INT=2     
AMTW51I MINRATE = 10,000               
AMTW51I INT = 2

Related topic



 