Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops SYSPROG Services 6.3.

PWSCPMxx


This member contains Exception Monitor sampler control statements.

Syntax rules

The member names have the form PWSCPMxx, wherexx is alphanumeric (for example, PWSCPMFF, PWSCPM09, PWSCPMA9). Each member contains control statements specifying Exception Monitor services, their warning intervals, and appropriate threshold specifications.

The following syntax rules apply:

  • Separate the Exception Monitor service name from the specifications with a comma or at least one blank.
  • Enter comments by placing an asterisk in column 1.

Default

By default, the Exception Monitor Samplers listed in member PWSCPM00 are invoked when you begin Exception Monitor sampling.

Example

The following example is of a member called PWSCPMEX:

  • INT 60
  • ENQ 5,10
  • PAG 4,50
  • AIOR 2,*,250,A

The example contains three Exception Monitor sampler statements and a control statement:

  • The first statement (INT 60) specifies an interval rate of 60 seconds.
  • The second statement (ENQ 5,10) requests that warning messages be issued at five-minute intervals if any enqueue conflicts have existed for over 10 minutes.
  • The third statement (PAG 4,50) requests that warning messages be issued at four-minute intervals if the paging rate exceeds 50 over the preceding four minutes.
  • The fourth statement (AIOR 2,*,250,A) causes warning messages to be issued at two-minute intervals for each address space whose I/O rate exceeds 250 EXCPs per second over the preceding two minutes.


 