Status values
In the alarm definition views you can see the status of the alarm definition.
Following table describes the possible values for the status.
Status | Description |
---|---|
Active | The alarm definition is evaluating MainView data at the frequency specified by its schedule. |
AlarmMgrDown | Alarm Management is not executing. |
Disabled | The alarm definition is activated, but it is individually disabled. |
DisGrp | The alarm definition is activated, but its group is disabled. |
EvalCancelled | The alarm evaluation task was cancelled. |
EvalEnded | The alarm evaluation task ended. |
EvalRestarted | The alarm evaluation task restarted. |
InError | An error occurred while processing the alarm definition. |
Initializing | The alarm definition is activated, and it is being prepared for evaluation. |
NoTarg | The alarm definition is activated, but the service point specified in the alarm definitions not available. |
NotInSchedule | The alarm definition is activated, but its schedule indicates that it is not being evaluated. |
NotActive | The alarm definition is not active. |
ShutdownReq | Alarm Management shutdown has been requested. |
Related topic