Information
Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Infrastructure 7.1.

Configuration recommendations for MainView AutoOPERATOR


To facilitate the Best Practices discussed in this section, use the following 

MainView AutoOPERATOR

 parameter settings:


Library

Member

Parameter and recommended value

Description

UBBPARM

BBISSP00

ALRTRCVE=YES

Specifies that the BBI-SS PAS can receive product alerts from other BMC products

BBPARM

BBISSP00

MCTSIZE=4080 (or greater)

Specifies the total number of unique messages to be displayed on the message activity statistics panel

Specify MCTSIZE=4080 or greater. For efficient use of storage, the value should be a multiple of 510. The default is 510.

Tip: To determine an appropriate MCTSIZE value, run MainView AutoOPERATOR for about a week, display the Event Activity Statistics panel, note the number in the Unique field in the upper right corner of the panel, and increase the number to a multiple of 510. Specifying this number will ensure that the MCTSIZE value is sufficient for the number of unique message IDs processed by MainView AutoOPERATOR in a week.

BBPARM

AAOPRM00

RULESCAN=INDIVIDUAL

Specifies that each Rule Set can have its own (individual) automation strategy

UBBPARM

$$INSYS0

AEWALERT=YES

Specifies that exception monitors send messages to MainView AutoOPERATOR for use as Alerts

$$INSYS0 is a MainView SYSPROG Services member.

For more information about these parameters, see MainView AutoOPERATOR Customization Guide.


 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

MainView Infrastructure 6.3