Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Infrastructure 7.1.

Managing cross-system communication between BBI-SS PASs


This topic describes how to manage VTAM communication between BBI-SS PASs located on different system images.

Tip

The information in this topic applies to the following products only:

  • MainView AutoOPERATOR
  • MainView FOCAL POINT
  • MainView for CICS
  • MainView for DB2
  • MainView for DBCTL
  • MainView for IMS Online
  • MainView for MQ

The figure in Managing-cross-system-communication illustrates VTAM links that enable MainView products in a BBI-SS PAS on one system image to communicate with products on another system image.

To start, stop, and display communication links between BBI-SS PASs, issue one of the following BBI control commands from a terminal session, a MainView AutoOPERATOR EXEC, or an operator's console:

  • .START LINK
  • .STOP LINK
  • .DISPLAY LINK

The following table summarizes the use of these commands.

Control commands for VTAM links between BBI-SS PASs

Command

Keywords

Parameters

Description

DISPLAY|D

LINK|L

ALL| ssid

Logs status of all or specified communications links to this BBI-SS PAS

START|S

LINK|L

ALL| ssid

Starts communications link between the BBI-SS PAS subsystem and the current BBI-SS PAS or between all available BBI-SS PASs and the current BBI-SS PAS

START LINK attempts to open the ACB if it is not open.

STOP|P

LINK|L

ALL| ssid

Stops communications link between the BBI-SS PAS subsystem and the current BBI-SS PAS or all available BBI-SS PASs and the current BBI-SS PAS

To use these BBI control commands, use the following guidelines:

  • For command notation shown in table above, conventions are as follows:
    • Command and keyword abbreviations are shown as an alternate choice as indicated by a vertical line between them.
    • The symbolic word, ssid, represents a one- to four-character BBI subsystem ID.
  • For command syntax, use the following conventions:
    • Use a blank between commands and keywords.
    • Use an equal sign, blank, or comma between keywords and parameters.

See BBI-control-commands for further information about the use of BBI control commands.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*