Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Infrastructure 7.1.

Saving system entries


Use the SAVE command to save additions, changes, or deletions to a LOGGERxx member in the BBPARM parameter library.

The SAVE command is entered on the COMMAND line. You must be in edit mode before you can enter the SAVE command.

Note

The END command (or its corresponding PF key) also saves any changes that you made while in edit mode.

When the SAVE command is used, the Save MVLOGGER Parm Definition Member dialog is displayed.

Save MVLOGGER Parm Definition Member dialog

 Save MVLOGGER Parm Definition Member
 COMMAND ===>                                               SCROLL ===> PAGE

 Enter a Description in the space below

  Description Test System Logger Definitions

 END to exit saving changes
 CANCEL to exit without saving changes
 HELP to view related help
 RESET to reset to initial data
  • If you are saving changes to an existing logger definition member, this dialog shows the previously defined Description field value.
  • If you are saving a new logger definition member, this dialog is displayed with a blank Description field.

To save the logger definition member

  1. Enter a description of up to 40 characters (it will appear in the Description field on the LOGRDEFL view).
  2. Press END to save the description and any changes to the LOGGERxx member in the BBPARM library.When you return to either the LOGRDEF or LOGRDEFD view, the edit mode status field on the window information line has changed from (00 EDIT MOD) to (00 EDIT) to indicate that the edit lock is still active but all modifications have been saved.

 