Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Batch Optimizer (Advanced and Standard) 2.9.

Buffer number option


With the Buffer number option, you specify the number of buffers to allocate for a pipe.

Each buffer can contain one data block. This parameter determines the number of data blocks that can be in the pipe at any one time; it does not limit the total quantity of data that passes through the pipe. BMC recommends that you specify a value from 5 to 15. If more than one reader exists and the value in the Reader data option is set to N (for Next, so that each reader gets the next available unread block), the Buffer number value should be set slightly higher.

Buffer number parameters

Parameter

Description

Values

This option has a numeric value of 1-99

Default value

Value specified in JOPDEFRL

Subsystem parameter

BUFFNUM=[ n]





 