CA 11 considerations


CA 11 tracks the shadow steps in the original job and not the steps that are executing in XJS initiators. The U11ACTEX exit that is supplied by BMC identifies the steps that are executing in XJS initiators and disables CA 11 tracking for those steps.

The U11ACTEX exit does not impede the ability for CA 11 to perform a restart against a job that is under Job Optimizer control. This exit does not affect the tracking of jobs that are not under Job Optimizer control.

For installation instructions, see Installing-CA-11-USERMOD-U11ACTEX

 