Editing or viewing an MVS image


You can review or modify the information that is saved for an MVS image, including subsystem IDs and the option to start subsystems automatically during BatchPlex initialization.

To edit or view an MVS image definition in a BatchPlex

  1. Access the BatchPlex Definition panel.
  2. Position the cursor in the action entry image, type Enter.You can use the values that override the BatchPlex global options for an MVS image. These values include the started task names and subsystem IDs for the following subsystems:

    • BMC Software Primary Subsystem (subsystem ID BMCP)
    • MainView Batch Optimizer Subsystem (subsystem ID MBOS)
    • Extended Job Execution Subsystem (subsystem ID MBOX)

    The MVS Image Definition pop-up also includes an option to start subsystems automatically during BatchPlex initialization, a startup commands member name, and the number of initiators to be used on this image to split batch job steps.

    The following figure shows an example of the MVS Image Definition pop-up, where the definition indicates that the values of the BatchPlex global options should be used for this MVS image.

    Note

    The MVS Image Definition pop-up panel is scrollable and might include a More: field.

    MVS Image Definition pop-up panel example

     File   View   Applications   Options   Help                                  
     -------------------------------------------------------------------------------
                                MVS Image Definition                           of 5
     C                                                                         PAGE
         Command ===> _____________________________________________________         
     B                                                                              
         Type values or D (use global default) in fields below.                     
         Press Enter to continue.                                             07/17
                                                                              :51   
         BatchPlex name . . . . . . . . : BPLEX00                                   
         MVS image name . . . . . . . . : SYSI     System name, not SMF ID.         
         MVS image comment  . . . . . . . ___                    
                                                               More:     +          
     T                                    Value      Valid settings                 
     E   Automatically start subsystems . _          Y=Yes N=No                     
                                                                                   
         BMC Primary Subsystem Options                                            
            Started task name . . . . . . ________                                  
     .      Subsystem ID  . . . . . . . . ____                                      
     E                                                                              
     .   MAINVIEW Batch Optimizer Subsystem Options                                        
     .    F1=Help      F4=Prompt    F6=Defaults  F7=Bkwd      F8=Fwd                
         F12=Cancel                                                           ons   
     F
  3. (optional) Edit individual fields, if needed:
    1. Position the cursor in a field that you want to edit, and replace the current value with a new value.
    2. Repeat this step for each field that you want to edit.
  4. (optional) Press Enter to retain your changes.
  5. (optional) On the BatchPlex Definition panel, commit the changes to the control data set by choosing File > 2 (Save BatchPlex).The changed BatchPlex is changed, and the BatchPlex Definition panel is displayed.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*