MainView AutoOPERATOR parameters in AAOPRMxx
BBPARM members AAOPRMxx contain the parameters that control certain functions of MainView AutoOPERATOR.
To modify an AAOPRMxx member, type S in the Cmd field of the Dynamic Parameter Manager panel. The following figure shows an example of the panel.
You can use the ACTIVATE command or the BBI control command .RESET for BBPARM member AAOPRMxx to reset all of the values specified in AAOPRMxx and to restart all time-initated Rules that are currently defined. These actions also occur any time the BBI-SS PAS is restarted with WARM or COLD specified.
The Dynamic Parameter Manager can update AAOPRMxx with the changes, however the PAS must be restarted (warm or cold) for the changes to take effect.
Dynamic Parameter Manager panel
COMMAND ===> TGT ===> BBSYSA
Primary command: Add Date --- YY/MM/DD
Time --- 11:41:36
LC CMDS --- (S)elect, (B)rowse w/o Symbolic Substitution
(A)ctivate, B(r)owse w/ Symbolic Substitution
Cmd Member Lib VV.MM Created Changed Size ID
________
_ AAOALS00 1 01.11 YY/MM/DD YY/MM/DD 20:12 4 JDB1
_ AAOALS01 1 00.01 YY/MM/DD YY/MM/DD 13:30 3 JDB1
_ AAOARP01 1 00.01 YY/MM/DD YY/MM/DD 13:30 3 JDB1
_ AAOEXP00 1 02.26 YY/MM/DD YY/MM/DD 20:12 27 JDB1
S AAOPRM00 1 02.26 YY/MM/DD YY/MM/DD 20:12 27 JDB1
_ AAOTSP00 1 02.01 YY/MM/DD YY/MM/DD 20:12 12 JDB1
**************************** END OF MEMBERS ******************************
Use this panel to see a list of all the AAOALSxx, AAOARPxx, AAOEXPxx, AAOPRMxx, and AAOTSPxx members in BBPARM.
From this panel, you can
- use the line commands; refer to Line commands for the Dynamic Parameter Manager panel for more information
use the primary command ADD to add a new members
To add a new member or members, type the following command on the COMMAND line, wherexx is a new suffix for a new member:
ADD AAOPRM xx