EXEC Thresholds panel


Use the EXEC Thresholds panel to view or modify values that determine how many EXECs can run in your system in the Normal or high-priority queues, how many EXEC abends that you want to be able to support, and so on. The following figure shows an example of the EXEC Thresholds panel.

EXEC Thresholds panel

BMC Software ------------------- EXEC Thresholds ----------------- AutoOPERATOR
COMMAND ===>                                                 TGT  --- BBSYSA
                                                             DATE --- YY/MM/DD
                                                             TIME --- 11:41:52
              Member         Current
EXABCNT  ===>      3             3    # of ABENDS allowed before EXEC disabled
MAXNORM  ===>      5             5    Maximum concurrent Normal EXECS
MAXHIGH  ===>      3             3    Maximum concurrent High Priority EXECS
MAXNORMQ ===>      5             5    Maximum Normal EXECs Queued
MAXHIGHQ ===>      3             3    Maximum High Priority EXECs Queued
MAXHOTQ  ===>     10            10    Maximum Hot/First priority EXECs Queued
WARNLVL1 ===>     65            65    Initial threshold (percent)
WARNLVL2 ===>     80            80    Secondary threshold (percent)
SELLIM   ===>     10            10    Maximum depth for SELECT with WAIT(YES)
MAXTPUT  ===>      0             0    Maximum TPUT allowed in each EXEC
Press END to save changes,  CANCEL to cancel changes

This panel provides two columns of data:

  • on the left, the value of the parameters in the AAOEXPxx member for the target BBI-SS PAS

    You can enter your modifications on this side of the panel.

  • on the right, the value of the parameters that are currently in effect for the target BBI-SS PAS; these values cannot be edited

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*