Command Specifications for an object


Specify an object start, stop, cancel and recovery commands (or EXECs) on the Command Specification panel.

You can also specify post-start and post-stop EXECs that CSM schedules after CSM starts or stops the object.

The panel provides default start, stop and cancel commands and these defaults specify the most common choices for starting, stopping and canceling an object.

The format of the default commands are as follows:

  • #S objectname to start an object
  • #P objectname to stop an object
  • #C objectname to cancel an object

The following shows an example of the Command Specifications panel.

Figure 1. Command Specifications panel

BMC Software ---- Command Specifications for AAOCSM01 - Add ---- AutoOPERATOR
COMMAND ===>                                                  TGT --- KMZ1
Start Command/EXEC      ===> #S AAOCSM01_______________________________
                             __________________________________________
                             __________________________________________
User Post Start EXEC    ===> __________________________________________
Stop Command/EXEC       ===> #P AAOCSM01_______________________________
                             __________________________________________
                             __________________________________________
User Post Stop EXEC     ===> __________________________________________
Cancel Command/EXEC     ===> __________________________________________
Recovery Command/EXEC   ===> __________________________________________
Start Command Time Out  ===> 0002         Start Command Limit ===> 3___
Stop  Command Time Out  ===> 0002         Perform Count Reset ===> Y (Y/N)
Conditional Start       ===> N (Y/N)      Conditional Stop    ===> N (Y/N)
Enter END command to process and return to Detail Control, ENTER to continue

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

MainView AutoOPERATOR 8.1