Changing the use of CICS recoverable temporary storage


BMC Software occasionally starts a CICS transaction by using interval control services. This type of transaction must complete processing because of existing recoverable temporary storage definitions in the CICS Temporary Storage Table (TST).

If a conflict exists between the BMC Software temporary storage prefix and an existing temporary storage definition, the prefix that is used by BMC Software (CMRI) must be changed by applying the following ZAP:

NAME CMRINT2 CMRINT2
VER  00BC    C3D4D9C9
REP  00BC    xxxxxxxx (any nonrecoverable prefix)

For information about how to determine whether a conflict exists between the BMC Software temporary storage prefix and an existing temporary storage definition, refer to

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*