Activating and saving modified Rules
Saving a Rule occurs when the Rule Set to which the Rule belongs is explicitly saved and written to disk. To save a new Rule or changes made to an existing Rule, you must perform the following steps:
- Press PF3/END from the Rule Processor Detail Control Panel.The Rule Set Overview panel is displayed and any changes you have made to the Selection Criteria, Variable Dependencies, Action Specification, or ALERT Action(s) panel are saved to the Rule set.
- Type the primary command SAVE on the COMMAND line of the Rule Set Overview panel.Typing SAVE writes the displayed Rule Set to disk. If you do not save your changes to disk, your changes will be lost at the next subsystem cold start or if you issue the BBI command to reset Rule Sets.
If you press PF3/END from the Rule Set Overview panel before you save the Rule Set, Figure 1 is displayed.
Figure 1. Example of Confirm Rule Set panel
BMC Software ------------ Confirm Rule Set Modifications -------- INVALID INPUT
COMMAND ===> TGT --- BBSYSA
+----------------------------------------------------------------------------+
+ WARNING! Changes made to Rule Set AAORUL02 have not been saved. Those +
+ changes were one or more of the following: +
+ +
+ o A Rule was changed. +
+ o The status of a Rule was modified. +
+ o A Rule was added, deleted, inserted, or copied. +
+ o A Rule was moved. +
+ o The individual Rule Set strategy changed. +
+ o A FILTER was added or modified. +
+ +
+ Please do one of the following: +
+ +
+ - Enter SAVE to save AAORUL02 to the BBIPARM data set. +
+ - Enter NOSAVE to exit WITHOUT saving AAORUL02 to the BBIPARM data set. +
+ - Press END to return to Rule Set Overview. +
+----------------------------------------------------------------------------+If you press PF3/END on the Rule Set Overview panel and you have moved a Rule between Rule Sets, resulting in two Rule Sets that need to be saved, Figure 2 is displayed:
Figure 2. Example of Confirm Rule Set Modifications panel
BMC Software ----------- Confirm Rule Set Modifications --------- AutoOPERATOR
COMMAND ===> TGT --- DL73
+----------------------------------------------------------------------------+
+ WARNING! One or more Rule(s) were moved from Rule set RULAO73 to +
+ Rule set RULEXECS Both Rule sets should be saved. +
+ +
+ o RULAO73 was NOT SAVED +
+ o RULEXECS was NOT SAVED +
+ +
+ +
+ Please do one of the following: +
+ +
+ - Enter SAVE to save Rule set(s) from the above list that have not been +
+ saved to the BBIPARM dataset. +
+ - Enter NOSAVE to exit WITHOUT saving either Rule Set. +
+ - Press END to return to Rule Set Overview. +
+----------------------------------------------------------------------------+
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*