PAGING
The PAGING control statement causes the Extractor to collect paging and swapping data.
[SAMPLE={5000|nnnn}]
Monitoring modes | One PAGING statement can be specified for each monitoring mode, continuous (CPM) or intermittent (IPM). | |
Sampler and record types | The PAGING statement controls the PAGS sampler, which produces SMF type 71 records and CMF type 240-03 user records. | |
Analyzer statements and reports | AUXSTOR CMFSUM PERFSUM, PERFORM SRM STORAGE | Auxiliary Storage Report CMF Summary Report Performance Summary Report System Resources Manager Report Storage Management Report |
Parameters
The parameter for the PAGING control statement is:
SAMPLE= | specifies the number of milliseconds between data gathering cycles for the paging data being gathered The default and minimum value is 5000. Because this sampler causes high overhead, acceptable values are 5000 to 9999. |
---|
Example
The Extractor samples paging data every five seconds.