OMVS
The OMVS control statement causes the Extractor to collect data on MVS OpenEdition kernel activity.
[SAMPLE={1000|nnnn}]
Monitoring modes | One OMVS statement can be specified for each monitoring mode, continuous (CPM) or intermittent (IPM). | |
Sampler and record types | The OMVS statement controls the OMVS sampler, which produces SMF type 74-3 records. | |
Analyzer statements and reports | OMVS | OMVS Kernel Activity Report |
Other BMC Software products | The OMVS control statement is used by the CMF MONITOR Extractor only. | |
Restrictions | To run this control statement, the user ID under which the Extractor is running must be designated as a valid OMVS user ID. You can use the security system facilities for your system to define the user ID to OMVS. For more information about defining security for OMVS accounts, see the IBM manual z/OS UNIX System Services Planning. |
Parameters
The parameter for the OMVS control statement is:
SAMPLE= | specifies the number of milliseconds between data gathering cycles for the paging data being gathered The default value is 1000. |
---|
Example
The Extractor samples OpenEdition MVS kernel activity data every five seconds.