Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Monitor for CMF 6.3.

OMVS


The OMVS control statement causes the Extractor to collect data on MVS OpenEdition kernel activity.

OMVS
[SAMPLE={1000|nnnn}]

Monitoring modes

One OMVS statement can be specified for each monitoring mode, continuous (CPM) or intermittent (IPM).

Sampler and record types

The OMVS statement controls the OMVS sampler, which produces SMF type 74-3 records.

Analyzer statements and reports

OMVS

OMVS Kernel Activity Report

Other BMC Software products

The OMVS control statement is used by the CMF MONITOR Extractor only.

Restrictions

To run this control statement, the user ID under which the Extractor is running must be designated as a valid OMVS user ID. You can use the security system facilities for your system to define the user ID to OMVS. For more information about defining security for OMVS accounts, see the IBM manual z/OS UNIX System Services Planning.

Parameters

The parameter for the OMVS control statement is:

SAMPLE=

specifies the number of milliseconds between data gathering cycles for the paging data being gathered

The default value is 1000.

Example

OMVS  SAMPLE=5000

The Extractor samples OpenEdition MVS kernel activity data every five seconds.


 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*