Limited supportBMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Monitor for CMF 6.3.

CHANNEL (Extractor control statements)


The CHANNEL control statement causes the CMF MONITOR Extractor to collect channel path busy counts. The system records channel path statistics in the channel path measurement table. CMF MONITOR inspects this table at the beginning and end of each recording interval, so the CHANNEL control statement does not need a default sample rate.

CHANNEL

Monitoring modes

One CHANNEL statement can be specified for each monitoring mode, continuous (CPM) or intermittent (IPM).

Sampler and record types

The CHANNEL statement controls the CHNS sampler, which produces SMF type 73 records.

Analyzer statements and reports

CHANNEL Analyzer control statement

CMFSUM

PERFSUM, PERFORM

Channel Path Activity Report

CMF Summary Report

Performance Summary Report)

Other BMC Software products

The CHANNEL control statement is used by the CMF MONITOR Extractor only.

Parameters

There are no parameters for the CHANNEL control statement.

Example

CHANNEL

The CMF MONITOR Extractor collects channel path statistics from the channel path measurement table.



 