Limited support BMC provides limited support for this version of the product. As a result, BMC no longer accepts comments in this space. If you encounter problems with the product version or the space, contact BMC Support.BMC recommends upgrading to the latest version of the product. To see documentation for that version, see BMC AMI Ops Monitor for CMF 6.3.

FICONSW (Report control statements)


The FICONSW control statement produces the FICON Director Activity Report, which provides configuration and activity information about all FICON Directors (switches) to which the system was connected.

FICONSW
RANGE=sss|(sss,sss,sss:sss,,.....)]

The FICONSW Analyzer statement uses data collected by the FICONSW Extractor control statement.

FICONSW

Parameters

The parameter for the FICONSW control statement is as follows:

RANGE=

(optional) provides the means to select the FICON switches that are to be included in the CMF FICON Director Activity Report

If this parameter is specified, only the FICON switches whose IDs match an ID in the parameter will be included in the report. Others will be ignored. The range can be specified as:

  • a single switch devices address, such as RANGE=ssss
  • a list of single switch devices addresses, such as: RANGE=(ssss,ssss,ssss,......)
  • a range of switch devices addresses, such as RANGE=(ssss:ssss)
  • a list of ranges of switch devices addresses, such as RANGE=(ssss:ssss,ssss:ssss,.....)
  • or a combination of these, such as RANGE=(ssss,ssss,ssss:ssss,ssss,......)

Up to sixteen switches or switch ranges can be specified. Each value specified must be 3 or 4 hexadecimal digits (0 through F), and it must not be a duplicate of another. The values need not be in any particular sequence; however, a switch devices address range must be in ascending sequence.

Examples

The following examples illustrate the use of the FICONSW control statement.

Information
Example
FICONSW

This example produces the FICON Director Activity Report.

Information
Example
FICONSW RANGE=(0100:010F)

In this example, only FICON switches whose IDs are in the range of 0100 through 010F inclusive will appear in the FICON Director report



 