Navigating Analyzer Control Statements


Pop-up panels might appear when you view or specify a control statement parameter value.

Group Parameter panel

In Analyzer Control Statements, parameters are often grouped.

You can group parameters by enclosing each level of the parameter value in parentheses.

The sample CMF Analyzer JCL Builder—Group Parameter panel (see the following figure) displays the parameter’s name, its description, the control statement to which it belongs, and the group size.

The sample CMF Analyzer JCL Builder—Group Parameter panel (see the following figure) displays the following information about the parameter:

  • name
  • description
  • control statement to which it belongs
  • group size

For each parameter in the group, the panel lists the following information:

  • name
  • number
  • format
  • value (if any)
--------------- CMF Analyzer JCL Builder - Group Parameter --- Row 1 of 93
 Command ===>                                          Scroll ===> CSR    
                                                                         
 Statement: CYCLE - Names a unique time-date range                        
 Parameter: FROMTODT - Date/time range(s) to be assigned                 
                                                                         
 Group Count: 31                                                          
                                                                         
 Key new values, or enter line command to see or set each subparameter.   
 Press ENTER to continue, END to complete, or CANCEL to exit.             
                                                                         
 Sel     Name-#      Format                        Value                  
 ---  ------------ ----------- ------------------------------------------
  _    FROMTODT-1   <group>     (30MAR12:000001,30MAR12:120000)___________
  _    FROMTODT-2   <group>     (2012091:120001,2012091:240000)___________
  _    FROMTODT-3   <group>     __________________________________________
  _    FROMTODT-4   <group>     __________________________________________
  _    FROMTODT-5   <group>     __________________________________________
  _    FROMTODT-6   <group>     __________________________________________
  _    FROMTODT-7   <group>     __________________________________________
  _    FROMTODT-8   <group>     __________________________________________
  _    FROMTODT-9   <group>     __________________________________________

You can enter a parameter’s intended value on any parameter pop-up panel, whether the parameter is a group-level parameter or an elementary-level parameter. The value entered is accepted and passed to other levels of the parameter as you navigate from level to level.

Group Sub-Parameter panel

Consider the following CYCLE statement in a Control Statement Set:

CYCLE    , Names a unique time-date range
DAILY,   Name to be given (R)
((29MAY12:000001,29MAY12:120000),(29MAY12:120001,29MAY12:240000))

If you set the SP (Set Parameter) line command on the third line of the statement, the Group Parameter panel looks like the panel displayed in the following figure.

------------ CMF Analyzer JCL Builder - Group Sub-Parameter - Row 2 of 93
 Command ===>                                          Scroll ===> CSR   
                                                                        
 Statement: CYCLE - Names a unique time-date range                       
 Parameter: FROMTODT - Date/time range(s) to be assigned                 
                                                                        
 Subparameter Count: 2                                                   
                                                                        
 Key new value, or enter S line command to see each subparameter.        
 Press ENTER to continue, END to complete, or  CANCEL to exit.           
                                                                        
 Sel      Name       Format                        Value                 
 ---  ------------ ----------- ------------------------------------------
      FROM         <date:time> 29MAY12:000001                            
      TO           <date:time> 29MAY12:120000                            
 ******************************* Bottom of data *************************

The parameter value format has been determined and the values entered are validated.

Date/Time Parameter panel

If you enter an S (Select) line command to display the FROM date/time value in further detail, the panel below is displayed.

--------------- CMF Analyzer JCL Builder - Date/Time Parameter --------------
Command ===>                                                                   
                                                                              
Statement: CYCLE - Names a unique time-date range                              
Parameter: FROMTODT - Date/time range(s) to be assigned                        
                                                                              
Maximum Length: 20                                                             
                                                                              
Value....: 2012365:000001______________________________________________________
                                                                              
Key new value and press ENTER to continue, END to complete, or  CANCEL

In the following figure, the subparameter is displayed at its elementary level. Changes that you make here are passed to the higher-level parameter until they appear in the EDIT panel, replacing the previous panel.

---------------- CMF Analyzer JCL Builder - Date/Time Parameter --------------
 Command ===>                                                                   
                                                                               
 Statement: DATETIME - Overall date/time range for data selection               
 Parameter: FROMTODT - Start and end date/time range                            
                                                                               
 Maximum Length: 20                                                             
                                                                               
 Value....: 31MAR2012:000001____________________________________________________
                                                                               
 Key new value and press ENTER to continue, END to complete, or  CANCEL

Keyword Parameter panel

In the figure below, the REPORT parameter might have one of the values that appear in the Keyword list.

If a value is not selected, the value defaults to OVERVIEW.

------------- CMF Analyzer JCL Builder - Keyword Parameter  Row 1 of 3
 Command ===>                                                         
                                                                     
 Statement: CACHEACT - Cache Subsystem and Device Reports             
 Parameter: REPORT - Type of report to generate                       
                                                                     
 Value....: ________   Default: OVERVIEW                              
                                                                     
 Key new value, or select a value from the list below.                
 Press ENTER to continue, END to complete, or  CANCEL to exit.        
                                                                     
 Sel  Keyword                                                         
 ---  --------                                                        
      DEVICE                                                          
      OVERVIEW                                                        
      SUBSYS                                                          
 ***************************** Bottom of data ************************

Integer Parameter panel

The figure below displays the Integer Parameter panel.

---------------- CMF Analyzer JCL Builder - Integer Parameter ---------------
 Command ===>                                                                   
                                                                               
 Statement: CACHEACT - Cache Subsystem and Device Reports                       
 Parameter: THRESHLD - Device omission threshold                                
                                                                               
 Default: 500   Minimum: 250   Maximum Length: 9                                
                                                                               
 Value....: 1000____________
                                                                               
 Key new value and press ENTER to continue, END to complete, or  CANCEL

In addition to displaying the current value of the THRESHLD parameter, the panel displays relevant validation criteria acquired from the lexicon.

String Parameter panel

The figure below displays the String Parameter panel.

---------------- CMF Analyzer JCL Builder - String Parameter -----------
 Command ===>                                                           
                                                                       
 Statement: CACHEACT - Cache Subsystem and Device Reports               
 Parameter: SUBSYS - Subsystems to include in report

 Specify a string no longer than 12 characters.                        
                                                                      
 Value....: AC00:ACFF__________________________________________________
                                                                      
 Key new value and press ENTER to continue, END to complete, or  CANCEL

The colon in the SUBSYS parameter indicates a range of addresses beginning with AC00 and ending with ACFF.


 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*

CMF MONITOR 6.1