IOQ (Report control statements)
The IOQ control statement requests the I/O Queuing Activity Report.
IOQ
[IGNORE=INACTIVE]
[IGNORE=INACTIVE]
Parameters
The parameter for the IOQ control statement is as follows:
IGNORE= | provides the option to suppress the printing of coupling facilities that have zero activity during the reporting interval. When IGNORE=INACTIVE is defined, coupling facilities that have no activity during the reporting interval are omitted from the report. |
---|
Example
The following example illustrates the use of the IOQ control statement.
IOQ
The I/O Queuing Activity report is produced.