Alarm definitions
- Threshold, persistence, and filter criteria
- View, product, and contexts for which the criteria are established
- Message IDs and message text
- Monitoring frequency and time periods
- Hyperlinks to views, extended help, and data passed to BMC AMI Ops Automation
Threshold conditions are derived from thresholds in BMC AMI Ops Monitor for z/OS. Alarm definitions are stored in a zFS file that is allocated by the CAS. This file is read by Alarm Management at CAS initialization and whenever administrative functions are performed.
Threshold conditions are defined as one of five priority levels:
- Informational
- Warning
- Minor
- Major
- Critical
OpsM for z/OS ships distributed alarm definitions in BBACTDEF member BBDTDA. The ALRMDIST view, as shown in following Figure, lists the distributed alarm definitions, which can be installed by either typing ADD on the command line or using an ADD line command.
Using ALRMDIST to see a list of distributed alarm definitions
>W1 =ALRMDIST==========SJSCDAVM=*=========DDMMMYYYY==HH:MM:SS====MVMVS====D==13
- Distributed Alarms - Hide Fixed Section
Replace NO
CMD Alarm Library Group Description
--- Name-------- ------------ ------------ ------------
BBDCF000 BMC MVMVS CF CPU utilization excep
BBDCF001 BMC MVMVS CF storage utilization e
BBDCF002 BMC MVMVS CF structure storage exc
BBDCPU00 BMC MVMVS High CPU utilization
BBDCSA00 BMC MVMVS CSA Max threshold except
BBDCSA01 BMC MVMVS CSA allocated by termina
BBDDEV00 BMC MVMVS DASD slow down
BBDDEV01 BMC MVMVS Device response time exc
BBDJES00 BMC MVMVS Required jobs not runnin
BBDJOB00 BMC MVMVS Delayed due to resource
BBDJOB01 BMC MVMVS Job CPU exceptions
BBDRSV00 BMC MVMVS DASD RESERVE exceptions
BBDWLM00 BMC MVMVS Jobs are not meeting PI
- Distributed Alarms - Hide Fixed Section
Replace NO
CMD Alarm Library Group Description
--- Name-------- ------------ ------------ ------------
BBDCF000 BMC MVMVS CF CPU utilization excep
BBDCF001 BMC MVMVS CF storage utilization e
BBDCF002 BMC MVMVS CF structure storage exc
BBDCPU00 BMC MVMVS High CPU utilization
BBDCSA00 BMC MVMVS CSA Max threshold except
BBDCSA01 BMC MVMVS CSA allocated by termina
BBDDEV00 BMC MVMVS DASD slow down
BBDDEV01 BMC MVMVS Device response time exc
BBDJES00 BMC MVMVS Required jobs not runnin
BBDJOB00 BMC MVMVS Delayed due to resource
BBDJOB01 BMC MVMVS Job CPU exceptions
BBDRSV00 BMC MVMVS DASD RESERVE exceptions
BBDWLM00 BMC MVMVS Jobs are not meeting PI
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*