Saving Packet Trace data upon PAS recycle
Before you begin
You can pre-allocate a data set before you save Packet Trace upon recycle of the BMC AMI Ops Monitor for IP PAS. This process is not performed within the program.
Allocate the data set with the following attributes:
- Organization: PS
- Record format: VB
- Record Length: 27998
- Block Size: 32760
To save Packet Trace data upon recycle of the BMC AMI Ops Monitor for IP PAS
- From the EZIP menu, select Product Administration (EZADMIN) in the Utilities section and press Enter.
- From the EZADMIN menu, select MVIP Configuration Settings (MVIPCNFD), and press Enter.
- In the Save Pkt at Shutdown field, type YES or NO to enable or disable saving of Packet Trace data.
- In the Shutdown Packet Trace File field, type the name of the data set where BMC AMI Ops Monitor for IP should write the Trace data when the PAS is shut down.