Replicating a monitor service request
Use the following procedure to replicate a monitor service request.
On the AT view, type R (Replicate) in the CM field for a monitor service request.An example of a Replicate Resource Monitor dialog is displayed, with the values from the copied request duplicated in the dialog.
Replicate Resource Monitor
COMMAND ===> SCROLL ===> CSR
BPUSE - BFR POOL % IN USE
Monitor Attributes:
PARM BP0 (Identifier) START (hh:mm:ss)
INTERVAL 00:01:00 (hh:mm:ss) STOP (hh:mm:ss/mins)
WVAL 85 (Warning value) WIF 1 (Intvls to 1st msg)
WMSG (Log warnings to) WIN 1 (Message Intervals)
WLIM 10 (Warnings limit) RST HOT (HOT,PUR,QIS)
QIS YES (YES/NO)
TITLE BFR POOL % IN USE
PLOTMAX (Maximum PLOT X-Axis value)
RANGES (1-4 Range Distr. Upper Limits)
LOG (NO,ATSTOP,ATPD,ATINTVL,ATWARN)
ENTER to process the request
END to cancel the request
HELP to display related help(optional) Adjust the values as needed.To change a value, type over it.
For additional information about a field, press F1 for online Help.
- Press Enter.The monitor service request is started and the Active Monitors (AT or MONACTV) view is displayed with the new request listed.
Related topic
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*