XCFDATA
Monitoring modes | One XCFDATA statement can be specified for each monitoring mode, continuous (CPM) or intermittent (IPM). | |
Sampler and record types | The XCFDATA statement controls the XCFS sampler, which produces SMF type 74-2 records. | |
Analyzer statements and reports | XCF | Cross-System Coupling Facility Report |
Other BMC Software products | The XCFDATA control statement is used by the CMF Extractor. |
Parameters
The parameter for the XCFDATA control statement is as follows:
SAMPLE= | specifies the sampling rate for collecting XCF data in milliseconds The default is 30000 (30 seconds). The minimum is 5000 (5 seconds). The maximum is 60000 (60 seconds). |
---|
Example
XCFDATA
Invokes collecting XCF measurement data once every 30 seconds.