Default language.

PAGING


The PAGING control statement causes the BMC AMI Ops Monitor for CMF Extractor to collect paging and swapping data.

PAGING    
[SAMPLE={5000|nnnn}]

Monitoring modes

One PAGING statement can be specified for each monitoring mode, continuous (CPM) or intermittent (IPM).

Sampler and record types

The PAGING statement controls the PAGS sampler, which produces SMF type 71 records and CMF type 240-03 user records.

Analyzer statements and reports

AUXSTOR

CMFSUM

PERFSUM, PERFORM

SRM

STORAGE

Auxiliary Storage Report

CMF Summary Report

Performance Summary Report

System Resources Manager Report

Storage Management Report

Parameters

The parameter for the PAGING control statement is:

SAMPLE=

specifies the number of milliseconds between data gathering cycles for the paging data being gathered

The default and minimum value is 5000. Because this sampler causes high overhead, acceptable values are 5000 to 9999.

Example

PAGING  SAMPLE=5000

The Extractor samples paging data every five seconds.

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*