SENQR
OverviewThis control statement collects data on active reserve requests for a specified volume. The default is to record reserve activity for all volumes. Data is recorded in SMF79 subtype 6 records.
Specify VOLUME=vol to collect reserve data for the specified volume only. The data collected reflects reserves that are active or outstanding at the time the record is created. Reserve activity that occurs solely between recording intervals is not recorded.
Parameters
This statement has the following parameters:
VOLUME | serial numbers of the volsers for which data is collected You can specify up to 32 volsers. |
---|
Example
SENQ VOLUME=(MVS800,BAB003)
Data is collected on the reserves requested for volsers MVS800 and BAB003.