XCFDATA


The XCFDATA control statement causes the BMC AMI Ops Monitor for CMF Extractor to collect performance data about the activity of the Cross-System Coupling Facility (XCF).

XCFDATA
[SAMPLE={30000|nnnnn}]

Monitoring modes

One XCFDATA statement can be specified for each monitoring mode, continuous (CPM) or intermittent (IPM).

Sampler and record types

The XCFDATA statement controls the XCFS sampler, which produces SMF type 74-2 records.

Analyzer statements and reports

XCF

Cross-System Coupling Facility Report

Other BMC Software products

The XCFDATA control statement is used by the CMF Extractor.

Parameters

The parameter for the XCFDATA control statement is as follows:

SAMPLE=

specifies the sampling rate for collecting XCF data in milliseconds

The default is 30000 (30 seconds). The minimum is 5000 (5 seconds). The maximum is 60000 (60 seconds).


Example

XCFDATA

Invokes collecting XCF measurement data once every 30 seconds.

 