FICON Director Activity Report


The FICON Director Activity Report provides configuration and activity information for all FICON Directors (switches) to which the system was connected when the Extractor recorded the data.

You can use this report to see how each FICON switch was configured and how it was being utilized

The FICON Director Activity Report is produced by using the FICONSW Analyzer control statement. This report processes SMF 74-7 records that are created by the FCSW sampler. That sampler is started by the FICONSW Extractor control statement.

This report consists of two sections:

  • IODF Section
    The Input/Output Definition File (IODF) is a VSAM linear data set that contains I/O definition information. This section of the report identifies the number and name of the IODF that was in use at the time the data was collected by the Extractor.
  • FICON Director Section
    This section of the report displays information about each FICON switch that was detected. This section also displays information about all of the ports that are assigned to each switch and how each port was being utilized during the recording period.

Important

The information shown for each port includes all of the I/O that is directed through this port, regardless of which system requests the I/O. That is, the measurements shown are not specific or limited to the system on which the Extractor gathered and recorded the measurements.

An example of the FICON Director Activity Report is shown in the following figure.

PRODUCED BY CMF ANALYZER (v.r.mm  RSL yymm )                   FICON DIRECTOR ACTIVITY REPORT                      RPTSEQ     3 PAGE      5
BMC SOFTWARE, INC.                                          BMC ENGINEERING                             REPORT DATE: DD MMM YY 10.52
ACTL 25 OCT YY 16.25.00  25 OCT YY 17.24.28                                                             SYSTEM ID: SJSC     Z v.rr.n


BASED ON REC TYPE/# RECS/# SAMPLES/REC HOURS:  74-7/24/12/0.99

----------------------------------------------------------- IODF SECTION -----------------------------------------------------------
IODF SUFFIX: 03   CREATED: 09/29/YYYY - 16.21.34   IODF DSN: BMCS.IODF03
ACTIVATED: IPL        CHANGED THIS REPORT PERIOD: NO

------------------------------------------------------ FICON DIRECTOR SECTION ------------------------------------------------------

SWITCH DEVICE: 0105   SWITCH ID: 61   TYPE: 006140   MODEL: 001   MFR: MCD   PLANT: 01   SERIAL: 00000131278E

 PORT     -CONNECTION-     AVG. FRAME     --AVG. FRAME SIZE--     TRANSFER RATE(MB/SEC)     ERROR
 ADDR      TYPE    ID      PACING(MS)       READ       WRITE        READ        WRITE       COUNT
 --      ------  ----      ----------     -------     -------     --------     --------     -----

 04      CU      ----              0         644       1,546        0.118        0.443         0
 05      ------  ----              0       1,604         181        0.187        0.009         0
 06      ------  ----              0       1,515          53        0.019            0         0
 07      ------  ----              0       1,518       1,041        0.119        0.067         0
 08      ------  ----              0           0           0            0            0         0
 09      ------  ----              0       1,497         553        0.117        0.030         0
 0A      ------  ----              0          68       1,911            0        0.011         0
 0B      ------  ----              0           0           0            0            0         0
 0C      CHP-H     E8              0       1,645          73        2.162        0.026         0
 0D      CHP-H     E9              0       1,961          76        2.314        0.007         0
 0E      CHP-H     EA              0       1,661          68        3.945        0.044         0
 0F      CU      ----              0          68       1,645        0.024        2.162         0
 10      CU      ----              0          76       1,961        0.007        2.314         0
 11      CU      ----              0          68       1,661        0.044        3.945         0
 12      CHP-H     E2              0       1,798       1,202        1.036        0.198         0
 13      CHP-H     E4              0       1,799       1,220        1.037        0.204         0
 14      CU      ----              0       1,202       1,798        0.198        1.036         0
 15      CU      ----              0       1,220       1,799        0.204        1.037         0
 16      CHP-H     F3              0         465       1,002        1.480        3.984         0
 17      CHP-H     F4              0         455       1,002        1.427        3.944         0
 18      CU      ----              0       1,002         465        3.984        1.480         0
 19      CU      ----              0       1,002         455        3.944        1.427         0
 1A      CHP-H     F0              0         263         989        1.075        3.362         0
 1B      CU      ----              0         997         264        3.356        1.073         0
 1C      CHP-H     F1              0         258       1,002        1.052        3.409         0
 1D      CU      ----              0       1,002         258        3.409        1.052         0
 1E      CHP       F0              0       1,060         640        0.816        0.330         0
 1F      CU      ----              0         656       1,079        0.325        0.814         0
 20      CHP       F2              0         765         924        0.828        0.892         0
 21      CHP       F3              0           0           0            0            0         0
 22      CU      ----              0       1,474         473        6.771        0.904         0
 23      CHP       F0              0          92       1,621        0.038        2.937         0
 24      CHP       E5              0           0           0            0            0         0
 25      CHP       F2              0          92       1,621        0.038        2.942         0
 26      CHP       F4              0          71         171            0            0         0

FICON Director Activity Report field descriptions

The table below describes each field in the FICON Director Activity Report.

Field

Description

IODF Section

IODF SUFFIX

two-character hexadecimal suffix for the IODF data set name

CREATED

date and time that this IODF data set was created

IODF DSN

data set name of the IODF

ACTIVATED

text indicating how this IODF was activated

CHANGED THIS REPORT PERIOD

text indicating whether the IODF was changed during this reporting period

FICON Director Section

SWITCH DEVICE

four-digit hexadecimal address of the FICON switch

SWITCH ID

two-digit hexadecimal switch ID that is associated with this FICON switch

Important

The SWITCH ID of cascaded switches is shown as ‘**’.

TYPE

device type of the FICON switch

MODEL

model number of the FICON switch

MFR

manufacturer of the FICON switch

PLANT

plant number where the FICON switch was manufactured

SERIAL

serial number of the FICON switch

PORT ADDRESS

hexadecimal address of the port on the FICON switch

CONNECTION TYPE

identifies the type of connection; the values that you can see are as follows:

  • CHP—denotes a channel path
  • CHP-H—denotes a channel path of the system on which the Extractor gathered and recorded the data
  • CU—denotes a control unit
  • SWITCH—denotes a switch

If the unit is not unique, dashes are displayed. For example, for CTC channels there might be a CU and a CHP connected to the same port.

CONNECTION ID

hexadecimal identifier of the connector; dashes are shown if the connection type is SWITCH, CU, or is not unique

AVG. FRAME PACING (MS)

average time (in milliseconds) that a frame had to wait before it could be transmitted during the report period

Important

While the unit of time on the report is milliseconds, it is displayed in four decimal places, the equivalent of tenths of microseconds.

AVG. FRAME SIZE

average frame sizes (in bytes) used in reads and writes during this report period

TRANSFER RATE (MB/SEC)

rate (in million bytes per second) that data was read and written during the report period

ERROR COUNT

number of errors that were encountered during the report period

 