XCF
The report is divided into three sections:
System Summary
This section contains information about XCF activity for each pairing of source and target systems, including activity within each system.
Path Utilization
This section contains information about XCF activity for each path between or within systems.
Detail Report
This section contains information about XCF activity for each member. You can sort the information in this section by using the ORDER parameter.
The XCF statement uses data collected by the XCFDATA Extractor control statement.
Parameters
The parameters for the XCF control statement are as follows:
TYPE= | specifies the type of reports to be generated as one of the following values:
|
---|---|
ORDER= | specifies the ordering of the information displayed in the DETAIL report This operand has no effect on the SUMMARY reports. The DETAIL report contains a summary line that is calculated based on the first parameter of ORDER. For example, if you specify ORDER=GROUP,SYSTEM,MEMBER, the values on the summary line are calculated based on groups. If all three values are specified, the order of display for the DETAIL report follows the sequence in which the values are specified. If one or two values are specified, the order of display for the DETAIL report starts with the value or values specified, and follows with the remaining values in the default order. |
Examples
These examples show what reports are generated, given the parameters that are specified in the control statement: