CREVIEW view
The following figure is displayed:
COMMAND ===>
CURR WIN ===> 1 ALT WIN ===>
W1 =CREVIEW==========(BCVWBALL=*=======)ddmmmyyyy=hh:mm:ss====MVCICS===D===16=============================
CMD Region CICS SMF APPLID SYS Start Start Sec --- --- -------- -------- S U F F I X E S --- ---- --- --- ---
--- Name Release ID ID Date Time Act SIT MCT PLTPI PLTSD RST SRT CLT FCT PDIR TCT TST XLT
BCVDA70C 0700 SJSC BCVDA70C A70C 14AUG2018 08:49 No 6$ MA PP 1$
BCVDA71C 0710 SJSC BCVDA71C A71C 14AUG2018 07:13 No 6$ MA PP 1$
BCVDA72C 0720 SJSC BCVDA72C A72C 14AUG2018 05:02 No 6$ MA DFHPLTPP DFHPLTPP 1$
Usage notes
The CREVIEW view can be used as the starting point for reviewing a region’s SIT parameters. Use the hyperlinks that are described in the following table to display specific SIT parameters and their values.
Field | Data displayed | ||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Region Name | EZCREV Easy Menu Each option on this menu provides a hyperlink to a CREVDn detail view, which displays a group of SIT parameters and their values. | ||||||||||||||||||||||||||||||||||||||||||
Sec Act | The hyperlink for this field displays the CREVSECU view. This CREVSECU view displays security-related system initialization table (SIT) parameters. IBM CICS security processing uses these SIT parameters. Each field in this view hyperlinks to a CREVDn detail view which includes that SIT parameter. | ||||||||||||||||||||||||||||||||||||||||||
SIT Suffix | The following table lists the additional SIT suffixes that support IBM CICS PTF UI53174 and UI53175 and the views that provide additional information:
|
The following figure is displayed:
COMMAND ===>
CURR WIN ===> 1 ALT WIN ===>
W1 =CREVIEW==========(BCVWBALL=*=======)ddmmmyyyy=hh:mm:ss====MVCICS===D===16=============================
CMD Region CICS SMF APPLID SYS Start Start --- --- -------- -------- S U F F I X E S --- ---- --- --- ---
--- Name Release ID ID Date Time SIT MCT PLTPI PLTSD RST SRT CLT FCT PDIR TCT TST XLT
BCVDA70C 0700 SJSC BCVDA70C A70C 14AUG2018 08:49 6$ MA PP 1$
BCVDA71C 0710 SJSC BCVDA71C A71C 14AUG2018 07:13 6$ MA PP 1$
BCVDA72C 0720 SJSC BCVDA72C A72C 14AUG2018 05:02 6$ MA DFHPLTPP DFHPLTPP 1$
Usage notes
The CREVIEW view can be used as the starting point for reviewing a region’s SIT parameters. Use the hyperlinks that are described in the following table to display specific SIT parameters and their values.
Field | Data displayed | ||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Region Name | EZCREV Easy Menu Each option on this menu provides a hyperlink to a CREVDn detail view, which displays a group of SIT parameters and their values. | ||||||||||||||||||||||||||||||||||||||||||
SIT Suffix | CREVDX view This view is the first of three alphabetical lists of SIT parameter names; the other two lists are CREVDY and CREVDZ. Each field in each list provides a hyperlink to the CREVD n detail view that contains that SIT parameter. | ||||||||||||||||||||||||||||||||||||||||||
SIT Suffix | The following table lists the additional SIT suffixes that support IBM CICS PTF UI53174 and UI53175 and the views that provide additional information:
|
If you place the cursor on a CICS region name in the CREVIEW view and press Enter, the EZCREV view is displayed:
COMMAND ===> SCROLL ===> CSR
CURR WIN ===> 1 ALT WIN ===>
W1 =CREVIEW==EZCREV==(BCVDVPC==*=======)ddmmmyyyy==hh:mm:ss====MVCICS===D====1=
CICS SIT Menu
Target CICS region -> BCVCD720
.Applications +----------------------+ .Fields A-F
.Autoinstall | Place cursor on | .Fields G-R
.Basic Mapping Support | menu item and | .Fields S-Z
.CICS WEB Interface | press ENTER |
.Data Interchange +----------------------+
.Database
.Dispatcher Functions .Long Fields .System Startup
.DL/I .Miscellaneous .System Termination
.Dump .Monitoring .TCPIP / SSL
.Extended Recovery .RDO File Control .Temporary Storage
.File .Security .Terminal and LU
.ISC and Multiregion .Signon .Timer
.JAVA .Special Tracing .Trace
.Journaling .Standard Tracing .Transaction Backout
.Keystroke Retrieval .Storage Management .Transient Data
.Loading Programs .Supervisor Calls .VTAM
From EZCREV, you can select:
A category, such as Application
When you hyperlink from a category field, the detail view that contains that type of SIT parameters is displayed, except for Security which displays the tabular view CREVSECU.
- An alphabetic grouping, such as Fields A-F
When you hyperlink from an alphabetic field, an alphabetic list of SIT parameter names is displayed, as shown below.
COMMAND ===> SCROLL ===> PAGE
CURR WIN ===> 1 ALT WIN ===>
>W1 =CREVIEW==CREVDX===BCVDS67C=*========ddmmmyyyy==hh:mm:ss====MVCICS===D====1
Target BCVDM740
A-F... ADI.......... CERTEXPIRYWARN CSDBUFNI. DFLTUSER... ESMEXITS
G-R... AIBRIDGE..... CHKSTRM....... CSDDISP.. DIP........ FCQRONLY
S-Z... AICONS....... CHKSTSK....... CSDDSN... DISMACP.... FCT.....
AIEXIT....... CICSSVC....... CSDFRLOG. DOCCODEPAGE FEPI....
AILDELAY..... CILOCK........ CSDINTEG. DSALIM..... FLDSEP..
AIQMAX....... CLINTCP....... CSDJID... DSHIPIDL... FLDSTRT.
AIRDELAY..... CLSDSTP....... CSDLSRNO. DSHIPINT... FORCEQR.
AKPFREQ...... CLT........... CSDRECOV. DSRTPGM.... FSSTAFF.
APPLID....... CMDPROT....... CSDRLS... DTRPGM..... FTIMEOUT
AUTCONN...... CMDSEC........ CSDSTRNO. DTRTRAN....
AUTODST...... CONFDATA...... CWAKEY... DUMP.......
AUTORESETTIME CONFTXT....... DAE...... DUMPDS.....
AUXTR........ CPSMCONN...... DATFORM.. DUMPSW.....
AUXTRSW...... CRLPROFILE.... DB2CONN.. DURETRY....
BMS.......... CSDACC........ DBCTLCON. EDSALIM....
From CREVDn (or any of the other alphabetic lists), you can select a specific SIT parameter and hyperlink to the detail view that contains that parameter.
The G-R... hyperlink displays the CREVDY view, which contains an alphabetical listing of SIT parameters starting with the letters G to R inclusive.
The S-Z... hyperlink displays the CREVDZ view, which contains an alphabetical listing of SIT parameters starting with the letters S to Z inclusive.
CREVDn detail views
To display the system initialization table (SIT) parameters for a CICS region, issue the following command:
CREVDn target
where target is the name of the target CICS region, and n identifies a set of SIT parameters as follows:
Value | Definition |
---|---|
1 | Application Considerations |
2 | Miscellaneous |
3 | Terminal and LU Management |
4 | Database Settings |
5 | Extended Recovery Facility, TBP Exits |
6 | Keystroke Retrieval |
7 | Security, Sign-on |
8 | BMS, Journaling, File |
9 | Long Data |
A | System Startup, System Termination |
B | Autoinstall, Data Interchange |
C | RDO File Control |
D | Standard Trace, Special Trace |
E | Storage Management |
F | Dispatcher Functions, Timer |
G | ISC and MRO, Supervisor Calls, Loading Programs |
H | Monitoring, Trace |
I | CICS WEB Interface, TCP/IP, Java |
J | CICS SIT full long data fields |
K | Temporary Storage, Transient Data |
L | Dump |
M | VTAM |
X | Alphabetical list–A to F–of system initialization table (SIT) parameters Each list item is a hyperlink to the associated view. |
Y | Alphabetical list–G to R–of system initialization table (SIT) parameters Each list item is a hyperlink to the associated view. |
Z | Alphabetical list–S to Z–of system initialization table (SIT) parameters Each list item is a hyperlink to the associated view. |
The following figure shows a sample CREVD1 view.
COMMAND ===> SCROLL ===> PAGE
CURR WIN ===> 1 ALT WIN ===>
W1 =CREVD1============CICSPRD1=*========ddmmmyyyy==hh:mm:ss====MVCICS===D====1
Target... BCVCD680
Parameter Value O Description
--------- -------- - ------------------------------
Application Considerations
CMDPROT.. YES Command Protection Option
CMDSEC... ASIS Global Command Security
CWAKEY... CICS Y CWA Storage Key
DISMACP.. YES Disable MACRO programming
INITPARM. 2F682048 Y Initial Parm Data
LGNMSG... NO VTAM Logon Data Option
OPERTIM.. 120 WTO Timeout Interval
TCTUAKEY. CICS Y TCT User Area Key
TCTUALOC. BELOW TCT User Area Location
Usage notes
- Each CREVDn detail view presents one or more logical groupings of SIT parameters. As a group, the CREVDn views provide the complete list of SIT parameters.
- Each CREVDn detail view shows the name of the SIT parameter, its current value, and whether the original value was overridden by a SYSPARM or SYSIN change.
- Some CREVDn detail views have default hyperlink fields defined that provide links from:
A storage address to the DUMP view of the associated data
An example of this type of hyperlink is the INITPARM value on the CREVDA view.- A parameter, whose data is too long to display in a category view, hyperlinks to CREVD9, the Long Data view
An example of this type of hyperlink is the GMTEXT parameter on the CREVD3 view.