Using static BBIJNT00 entries


JNT entries that are created from elements defined in BBPARM member BBIJNT00 are considered static definitions. They are created when the BBI-SS PAS initializes and cannot be removed or modified for the life of the BBI-SS PAS. These entries override any of the dynamic types of JNT entries.

These elements should only be used to define IBM CICS targets when the relationship between the CICS and the BBI-SS PAS being used to manage it does not change. This is because changing this relationship requires modification of the BBIJNT00 member on each BBI-SS PAS in the PAS-PLEX and restarting them.

For more Information about creating BBIJNT00 elements, see Defining BBI-SS PAS suffixes and target system parameters

Special considerations

Do not create a BBIJNT00 definition that uses an ALIAS for the name of another CICS JOB or STC.



 