ESM resource definitions


The data preparation address space for BMC AMI Ops Insight must be able to retrieve view data from BMC AMI Ops Monitors to provide Detailed Analysis (aka probable cause) capabilities. 

The product currently queries for data from the following monitors and infrastructure:

  • BMC AMI Ops Monitor for Db2 (MVDB2)
  • BMC AMI Ops Monitor for CICS (MVCICS)
  • BMC AMI Ops Monitor for z/OS (MVMVS)
  • BMC AMI Ops Monitor for IMS (MVIMS)
  • Infrastructure Plex Manager (PLEXMGR)

The following table describes the minimum required access to the BMC AMI Ops Monitor products.  The USERID of the Data Preparation address space requires access to the following resources. By default, they are part of the Facility class. 

Note

Over time more products will be added to this list.

Description

Resource Name

Access

Notes

CAS Connect

BBM.<casid>.CN

READ

 

Access to Product

BBM.<system>.<product>.<context>.TA

READ

1

Cross LPAR Access

BBM.<product>.<context>.<LPAR>.XA

READ

2

Record access

BBM.<product>.<context>.<inttable>.OD

READ

3

Generic Record access

BBM.*.*.*.OD

READ

3. Give access to all data for all products

PLEXMGR/CYA70

BBM.PLEXMGR.*.CYA70.OD

READ

3

MVDB2/PL100

BBM.MVDB2.*.PL100.OD

READ

3

MVDB2/PU100

BBM.MVDB2.*.PU100.OD

READ

3

MVDB2/PY300

BBM.MVDB2.*.PY300.OD

READ

3

MVDB2/PF100

BBM.MVDB2.*.PF100.OD

READ

3

MVCICS/KTA10

BBM.MVCICS.*.KTA10.OD

READ

3

MVCICS/KRF00

BBM.MVDB2.*.KRF00.OD

READ

3

MVIMS/ FPA60

BBM.MVIMS.*. FPA60.OD

READ

3

MVMVS/ DC101

BBM.MVMVS.*. DC101.OD

READ

3

MVMVS/ DCE47

BBM.MVMVS.*. DCE47.OD

READ

3

MVMVS/ DCE48

BBM.MVMVS.*. DCE48.OD

READ

3

MVEXP/ WIF01

BBM.MVEXP.*. WIF01.OD

READ

3

Notes for table

  1. To give generic access to all BMC AMI Ops Monitors, give the USERID associated with the Data Preparation address space READ access to BBM.*.*.*.TA.  Otherwise define unique resources for each product listed above and give the Data Preparation address space USERID READ access.
  2. If you have secured queries across sysplexes, the Data Preparation address space requires access.  Normally BMC AMI Ops Insight Monitors at least one Sysplex/Db2 Group from a single Data Preparation address space.  To provide Detailed Analysis, the Data Preparation address space needs to query your BMC AMI Ops Monitors on any of those systems. This requires cross-LPAR access.  You can give the USERID associated with the Data Preparation address space access to any monitor running on any system and then give the USERID read access to BBM.*.*.*.XA. Optionally, you can limit based on product, context, or LPAR. 
  3. The product queries your BMC AMI Ops monitors.  You can provide access to all monitors and all data or you can limit to specific products and specific records.  If you prefer the more restricted access, all products and records that the product currently requests are listed in the table.


Related topics

 

Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*