Default language.

Refreshing view data in MainView Explorer


The data displayed in a view is static. When you refresh the data in a view, new data is retrieved from the host and displayed in the view. Refreshing data in a view automatically refreshes the data in any alternate form of the view, such as a chart or detail view. You can refresh data manually, or automatically at a specified interval.

Important

  • You cannot refresh the Plex Map view automatically.
  • If you are using the Automatic Connection facility (or AutoConnect), you cannot refresh the CICS region views. A static JNT entry is required to refresh the CICS region views.

To manually refresh data in views

  1. On the view toolbar, click the Refresh GUID-71614026-8B0E-41E5-9D0A-E9F86A8BF4E9-low.png button.

To automatically refresh data in views

  1. On the view toolbar, click the Auto-Refresh GUID-19D5C6D1-1CDC-474E-819A-35A79300D966-low.png button.

    Data in the view is refreshed automatically.

    By default, the rate is 30 seconds. Your site administrator might have changed this default. You can also change the rate for your individual use.

To set the automatic refresh rate

Use this procedure to set a refresh rate for your own use. This refresh rate is valid for your current system only.

  1. From any view (except the Plex Map view), perform one of the following actions:

    • On the view toolbar, click the Properties GUID-56C33B05-4151-4EF1-8A36-63C1A0D33549-low.pngbutton.
    • Right-click the view tab or the blank part of the view toolbar, and select Properties.

    The Properties dialog box is displayed.
     

  2. On the Refresh tab, use the drop down to select a refresh rate, from 15 seconds to 24 hours.
     
  3. Perform one of the following actions:
    • To set the rate and start the refresh cycle, click the Start button.
    • To set the rate without starting the cycle, click the Close button.

To stop automatic data refresh

  1. From a view that is in auto-refresh mode, perform one of the following actions:
    • On the view toolbar, click the Auto-Refresh GUID-19D5C6D1-1CDC-474E-819A-35A79300D966-low.pngbutton.
    • Open the Refresh tab of the Properties dialog box and click the Stop button.

 