Default language.

Configuration recommendations for BMC AMI Ops Automation


To facilitate the Best Practices discussed in this section, use the following BMC AMI Ops Automation parameter settings:


Library

Member

Parameter and recommended value

Description

UBBPARM

BBISSP00

ALRTRCVE=YES

Specifies that the BBI-SS PAS can receive product alerts from other BMC products

BBPARM

BBISSP00

MCTSIZE=4080 (or greater)

Specifies the total number of unique messages to be displayed on the message activity statistics panel

Specify MCTSIZE=4080 or greater. For efficient use of storage, the value should be a multiple of 510. The default is 510.

Tip: To determine an appropriate MCTSIZE value, run BMC AMI Ops Automation for about a week, display the Event Activity Statistics panel, note the number in the Unique field in the upper right corner of the panel, and increase the number to a multiple of 510. Specifying this number will ensure that the MCTSIZE value is sufficient for the number of unique message IDs processed by BMC AMI Ops Automation in a week.

BBPARM

AAOPRM00

RULESCAN=INDIVIDUAL

Specifies that each Rule Set can have its own (individual) automation strategy

UBBPARM

$$INSYS0

AEWALERT=YES

Specifies that exception monitors send messages to BMC AMI Ops Automation for use as Alerts

$$INSYS0 is a BMC AMI Ops SYSPROG Services member.

For more information about these parameters, see Customizing BMC AMI Ops Automation after installation.

 