Specifying product initialization within the z/OS PAS
All of the products are initialized by default. However, you can suppress the initialization of one or more products by using BBATSP00.
To control product initialization within the z/OS PAS
- Copy hlq.BBSAMP member BBAMVCPY to a private JCL library (where hlq is the high-level qualifier that is used for BMC AMI Ops Monitor for UNIX System Services data sets at your site).BBAMVCPY contains JCL to execute IEBCOPY, which will copy BBPARM member BBATSP00 to a UBBPARM library.
- Customize the JCL in BBAMVCPY by following the instructions at the top of the member.
- Submit the job.
- Review the job output to verify that the IEBCOPY job was successful.
In UBBPARM member BBATSP00, use the following syntax to enable or disable a product:
<product>
<name> ppppp </name>
<server> ssssssss </server>
<target> tttttttt </target>
<enable | disable />
</product>The variables are specified according to the following table:
ppppp
One of the following product abbreviations:
CMF
BMC AMI Ops Monitor for CMF
MV390
BMC AMI Ops Monitor for z/OS
MVUSS
BMC AMI Ops Monitor for UNIX System Services
MVSPS
BMC AMI Ops SYSPROG Services
MVVP
MainView VistaPoint
ssssssss
One- to eight-character job name of the z/OS PAS
tttttttt
One- to eight-character name of the context for the z/OS PAS
- To disable a product, change <enable/> to <disable/> in BBATSP00.
- Save the member and restart the PAS.
Tip: For faster searching, add an asterisk to the end of your partial query. Example: cert*